Structure and function of the control head, Characteristics, English – Burkert Type 1066 User Manual

Page 10

Advertising
background image

8 - 1066

T

ECHNICAL

D

ATA

english

Structure and Function of the Control Head

The Type 1066 control head is used to control pneumatically operated process valves from various
manufacturers. Depending on the configuration, it can be fitted with up to three solenoid valves (pilot
valves) for control of the process valve and with a maximum of three height-adjustable inductive
proximity sensors for position feedback. One of these sensors can also be an external sensor
(Attachment via 3-pole screw clamp on printed circuit board).

Characteristics

With the Type 1066 control head, there is a de-central solution for driving the process valves in addition to
the intended central solution for valve blocks. The advantages of this solution in the form of the compact
control head unit with the pilot valves and optionally usable field bus interfaces are:

Lower installation outlay.

Simple commissioning.

Short response times due to the short distance between the pilot valve and the
process valve.

Main areas of application:

Foodstuff industry (e.g. dairies)

Chemical industry

Pharmaceutical industry

Cosmetics industry

Breweries

Adjustment of proximity
sensor 2

Proximity sensor 2

Cover plate

Solenoid valve 3

Housing

Exhaust air

Valve 3

Valve 2

Valve 1

Compressed air

Interface to the
process valve

Valve flange

Marking for

mounting the cover

Proximity sensor 1

Electrical connection

Column with spindle

Adjustment of the

proximity sensor 1

Printed card

Pneumatic connections

Solenoid valve 2

Solenoid valve 1

Adjustment throug
these holes

NOTE

For sealed fieldbus modules, pay attention to the numbering of the proximity switch on the
circuit board / the identification on the device, since deviations from the numbering in the
drawing below are possible.

Advertising