installing a clamp fitting

Make sure the seals are in good condition.

Place seals adapted to the process (temperature,
fluid type) in the grooves of the Clamp fitting.

Fix the Clamp fitting to the pipe by means of a clamp collar.

installing a flange fitting

Make sure the seals are in good condition.

Place seals adapted to the process (temperature,
fluid type) in the grooves of each connection.

Make sure the seal remains in the groove while
tightening the flange.

Tighten the flange to fix the fitting to the pipe.

English

41

8. mAinTenAnce
Safety instructions

danger

risk of injury due to high pressure in the installation.
• Stop the circulation of fluid, cut-off the pressure

and drain the pipe before loosening the process

connections.

risk of injury due to high fluid temperatures.
• Use safety gloves to handle the fitting.
• Stop the circulation of fluid and drain the pipe before

loosening the process connections.

• Keep all easily flammable fluid or material away from the

fitting.

risk of injury due to the nature of the fluid.
• Respect the prevailing regulations on accident preven-

tion and safety relating to the use of aggressive fluids.

English

41

42

Warning

risk of injury due to non-conforming maintenance.
• Maintenance must only be carried out by qualified and

skilled staff with the appropriate tools.

• Ensure that the restart of the installation is controlled

after any interventions.

cleaning

note

the fitting may be damaged by the cleaning product.
• Clean the fitting with a cloth dampened with water or

a detergent compatible with the materials the fitting is

made of.

English

43

9. SpARe pARTS And

AcceSSoRieS

attention

risk of injury and/or damage caused by the use of
unsuitable parts.
Incorrect accessories and unsuitable spare parts may
cause injuries and damage the fitting and the sur-
rounding area.
• Use only original accessories and original spare parts

from Bürkert.

Accessories

order code

certificate
Certificate 3.1

440 790

Certificate 2.2

440 789

Roughness certificate

444 898

Calibration certificate

550 676

FDA approval

449 788

English