background image

32

12-36 V DC

+

-

1

3

2

V+

0 V DC

+

-

Pulse input on external instrument

Terminal block of the 2508

Power supply

Fig. 6: PNP wiring of the Hall version

1

2

3

4

1 : V+ (12-36 V DC)

2 : NPN transistor output

3 : 0 V DC

4 : Not connected

Fig. 7: Pin assignment of the fixed connector, Hall Low

Power version

English

33

1

3

2

+- IN

Terminal block of the 2508

IN = pulse input on remote transmitter

Remote transmitter

Fig. 8: NPN wiring of the Hall Low Power version

1

2

3

4

1 : Not connected

2 : Sinus output

3 : Sinus output

4 : Not connected

Fig. 9: Pin assignment of the fixed connector, sinus

version

English

33

34

1

3

2

+-

IN

Terminal block of the 2508

IN = pulse input on remote transmitter

Remote transmitter

Fig. 10: Wiring of the sinus output of a sinus version

English

35

8. mAinTenAnce
safety instructions

danger

risk of injury due to electrical voltage.
• Shut down and isolate the electrical power source

before carrying out work on the system.

• Observe all applicable accident protection and safety

regulations for electrical equipment.

risk of injury due to high pressure in the installation.
• Stop the circulation of fluid, cut off the pressure

and drain the pipe before loosening the process

connections.

risk of injury due to high fluid temperatures.
• Use safety gloves to handle the device.
• Stop the circulation of fluid, and drain the pipe before

loosening the process connections.

• Keep all easily flammable material and fluid away from

the device.

English