ELRO KT100 User Manual

Page 9

Advertising
background image

9

deviated from the program. The thermo-

stat then automatically switches back in

the programmed temperature. To devi-

ate from the comfort temperature follow

the same actions, but instead press .

4.6 Other settings

The function “CL/HT”

The thermostat can be connected to

a heating system or a cooling system.

The thermostat should be set on “HT”

for a heating system and on “CL” for a

cooling system. If necessary, adjust the

setting by pressing “mode” (15). Then

press “CL/HT” (13) until the desired

mode appears. Exit with “ok” (14).

The function “DLY”

The thermostat optionally can start your

heating system delayed (for a cooling

system, this is set by default). The ther-

mostat only starts your system after it

has been switched off for 5 minutes.

Press on “mode” (15) first to enable

the delay. Then press “DLY” (12) until

“DLY” appears on the display and exit

with “ok” (14). To turn off the delay, fol-

low the same procedure but make

sure that “DLY” is not shown in the dis-

play.

The function “1C/2C”

You can set the permissible temperature

fluctuation or “span”. The span deter-

mines how much the ambient tempera-

ture may increase or decrease before

the thermostat responds. For example:

with a span of 1°C and a comfort tem-

perature set to 20°C, the temperature

may decrease to a maximum of 19.5°C

(for a heating system) or increase to

20.5°C (for a cooling system) before the

thermostat responds. To set the span,

first press “mode” (15) and then press

“1C/2C” (11) until you see the desired

span in the display. Exit with “ok” (14).

5 Malfunctions

Malfunction

Cause

Solution

Information on the

display is not visible

- Batteries are empty

- Batteries placed wrong

- Replace

Strange characters

on display

- Failure in software

- Press the

reset key

Temperature is not

well regulated

- Thermostat is too close to a heat source,

exposed to the sun or draught

- The span is set too wide

- Set the span to 1 °C

- Move the

thermostat

6 Technical specifications

6.1 General specifications

Product description

Name: Programmable room thermostat

Model/Type: KT100

Technical product specifications

Batteries: 2 penlight alkaline type

AA/ LR6

Switching Voltage: 24V AC and 230V

AC

Switching Current: max. 6 Amp

Measuring Range: 0 .... 40°C

Adjustable Range: 5 ... 30°C

Measuring Accuracy: +/- 0.5°C

Temperature span: 1°C or 2°C

adjustable

Programs: 10 presets, 10 to be modified

0504_ELRO_KT100 thermostat_CH_130x73_2.indd 9

07-09-12 15:32

Advertising