CHAPTER 1 - GENERAL INFORMATION

Models HT86, HT86HT

1 - 2

Doc. No. 003162 Rev. F

Flow Transmitter

The flow transmitter measures the voltage differential (

D

V) produced by the temperature differential (

D

T) between

the active and reference RTDs for each individual sensing point. The flow transmitter amplifies the

D

V signal and

converts it into a signal that is temperature compensated and linearized. The linearized signals from the sensing
points are then averaged together and converted into the final output signal (4-20 mA, 0-5 Vdc, 0-10 Vdc, etc.) as
specified by the customer.

The flow transmitter has a diagnostic alarm. If a problem exists with a sensing point, a Light-Emitting-Diode (LED)
on the control board will flash to notify the customer.

Technical Specifications

Process connection

2 inch male NPT or 2 inch 150 lb. raised-face
carbon steel flange.

Number of sensing points

Up to and including 8 sensing points.

Insertion length

The duct dimensions at the measurement site
determine the insertion U-Length.

Material of construction

All wetted parts are 316 stainless steel with nickel-
braze, per MIL-B-7883 using AMS 4777

Local enclosure (flow element
terminal strip enclosure)

NEMA 4 enclosure with 1 inch female NPT
connection ports.

Operating pressure

Standard MT86 is 0-50 PSIG or higher on
application.

Operating temperature

Standard flow element: -50 to 350°F (-46 to
177°C).

High temperature (HT) element: -50 to 850°F
(-46 to 454°C).

Flow transmitter: 0 to +150°F (-18 to 66°C) with
LCD or -50 to 150°F (-46 to 66°C) without LCD.

Flow range

0.25 to 150 fps in gas under standard conditions
(14.7 PSIA @ 70°F).

Flow element assemblies

May have 1, 2, 3 or 4 separate flow element
assemblies. Must contain a minimum of 2 sensing
points per flow element.

Remote enclosure (flow transmitter
control circuit enclosure)

NEMA 4 enclosure with 1 inch female NPT
connection ports.

Input power

Standard 100-130 Vac or 200-270 Vac, 50/60 Hz,
50 watt maximum. Optional 24 Vdc, 50 watt max.

Output signal

4-20 mA current loop capable of driving a 1000
ohm load. Optional:

10-50 mA, 400 ohm load max.

0-5 Vdc, 2 mA current max.

1-5 Vdc, 2 mA current max.

0-10 Vdc, 2 mA current max.

Interconnecting cable

24 AWG (min.) 8-conductor shielded cable with
PVC insulation (100 feet maximum). Longer
distances are possible using a heavier gauge wire
for the heater circuit (see Table 2-1).

Turn down ratio

2:1 to 100:1 within flow element range customer
specified.

Accuracy

± 3% of full scale at the temperature of calibration;
±5% of full scale with temperature compensation
over a range spanning 200°F. Manufacturer
determines the accuracy for specific duct
configurations upon submittal of a fully completed
Multipoint Mass Flowmeter Application Data
Sheet.

Repeatability

± 1% of full scale.

Approvals

F.M., C.S.A., and CENELEC approvals are
available for all MT Series Multipoint Mass
Flowmeters.