HOMA TP GRP T Motor Voltage Change User Manual

Page 2

Advertising
background image

Publication

88FN2045A

Please Contact Technical Support At 203-736-8890 With Any Additional Questions

Please Be Prepared To Provide Pump Serial Number During Call

Page

2 of 5



4. Sometimes the housing will be difficult to

remove. Twist the housing ¼ turn (90
degrees), exposing the bottom of the
cable entry horn. Using a soft faced
hammer, gently tap the cable entry horn
to free the stator housing.



5. With stator housing removed, locate the

upper bearing spacer and the bearing
support washer. The upper bearing
spacer may still be inside of the housing.
Clean Place those items aside until
reassembly.










6. With motor disassembled, turn stator

housing upside down, and support it so it
is free standing. Stator windings and
cable leads must be visible and easy to
reach. Your unit should now look like
this. Gently remove all wires from around
the stator windings. Take care not to
damage the winding insulation. Do not
use sharp tools!!




Advertising