HOMA TP GRP T Motor Voltage Change User Manual

Page 3

Advertising
background image

Publication

88FN2045A

Please Contact Technical Support At 203-736-8890 With Any Additional Questions

Please Be Prepared To Provide Pump Serial Number During Call

Page

3 of 5


7. Separate the wire bundles as indicated,

and record the wire numbers in each
bundle.


If pump is wired for 208/230V, it will have 4
wire bundles. If pump is wired for 460V, it
will have 6 wire bundles.

Bundle 1 ___

___

___


Bundle 2 ___

___

___


Bundle 3 ___

___

___


Bundle 4 ___

___

___


Bundle 5 ___

___

___


Bundle 6 ___

___

___



Note: If the power cable is 4 lead, the wires
are color coded. If the power cable is 7 lead,
each individual wire will have a number on
cable sheath. The power leads will not have
a separate wire number.


8. To convert from 230V to 460V operation,

you will need to separate the wire
bundles, one at a time, and reconnect as
indicated below.


9. To perform the reconnection, locate the

wire bundle with wires 1, 7, and the
power lead. Cut wire connector from the
bundle, freeing individual wires. Strip
wire sheathing back ¼ in preparation for
reconnection.


10. Select wire number 1 and the power lead.

Reconnect these 2 wires with the
crimpable wire nut (close end connector).
Leave wire number 7 loose for now.


Advertising