4 installing the disk drives, 5 temperature setting – Advantech SPC-530 User Manual

Page 10

Advertising
background image

SPC-530 User's Manual

7

2.4 Removing the disk drive bay

2.4 Installing the disk drives

1. Open the top cover as in Figure 2.1. There is one independent disk drive bay on the front of the

chassis. Remove the four outer screws which mount the drive bay to the chassis. Slide the drive bay
toward the rear of the chassis, and lift it free of the chassis. See Figure 2.4 below.

2. Remove the front cover of the drive bay, and insert the drives into their proper locations in the drive

bay. See Figure 2.5.

2.5 Inserting the drives into the drive bay

2.5 Temperature setting

If the chassis interior temperature exceeds 65

o

C (149

o

F) (default setting), the LED changes color from

green to red. There is also an audio alarm. The LED remains red until the temperature drops below
63

o

C.

The default of the "RF_JMP" is PIN1-2: ON, which enables redundant power detection.

Temperature can also be selected (via SW1) on the alarm board inside the chassis:

SW1

1

2

TEMP

OFF

OFF

65

o

C

OFF

ON

55

o

C

ON

OFF

70

o

C

ON

ON

75

o

C

2.6 Alarm board

Advertising