Installation Manual

© Hydra-Flex Inc 2011

- 8 -


Feed Water Connection

**PRIOR TO CONNECTION, ENSURE THAT THE FEED LINES ARE FREE OF DEBRIS BY FLUSHING OUT THE
LINES FOR 15 MINUTES

• Connect pre-run main water supply line to pump inlet with hose

supplied.

o

Single operating pump: 1” MNPT

o

Dual operating pump: 1-1/2” MNPT












Pneumatic Connections

**IF AIR IS NOT REQUIRED FOR YOUR AQUA-LAB, PLEASE SKIP THIS
SECTION

• Connect pre-run 3/8" OD poly feed line to push connect fitting on the

side of the primary regulator



















• Connect 3/8” OD poly lines from arch to each port that will be

foaming



**If there are unused air ports, back out the individual line regulator
until air no longer flows