2.

Electrical Connections

a. Connect yellow homerun control cables to car wash control panel

(See diagram below for wiring schematic)

 Manifold Position below designates which port is associated to what color wire.

Example: If you want Presoak 1 to be on manifold port 2, then connect the green wire to

your controller relay for Presoak 1.

Schematic for Solenoid Valve Signal Connection

*****************

(NON - HFI supplied motor starter)*************

Manifold Port or Use

Main Trunk Cable

Wire Color

GROUND

Green/Yellow

NEUTRAL / COMMON

Blue

DO NOT USE

Brown

Port 1

White

Port 2

Green

Port 3

Yellow

Port 4

Grey

Port 5

Pink

DO NOT USE

Red

(Left to right on water manifold, top to bottom on air valves refer to diagram on page 6)

b. Wire each leg of the power from your starter to each pump

i.

See diagram on pump for wiring schematic or pump manual