Installation and Set Up

1. Unpack from crate and inspect for damages
2. Anchor Mounting bracket to the wall in the desired location using three ¼” wall anchors.

a. Make sure that the mounting bracket is level

3. Hang CS1 on mounting bracket
4. Plumb water inlet using attached ½” push to connect fitting or remove and use the 3/8” NPT to adapt to

the fitting of your choice.

5. Plumb the air inlet using 3/8” poly flow hose ( a minimum of 60psi is required to open the valve

properly)

6. Plumb the solution outlet to the desired location using 3/8” poly flow tubing or other hose of your

choice.

7. Optional - Plumb the air outlet tubing using 3/8” poly flow tubing to a convenient location as near the

gun as possible and tee into the solution line and install check valve on the air line.

8. Connect the gun with foam generator to the end of the solution line
9. Plug the 120VAC cord into a dedicated 20 amp plug in
10. Turn the on / off switch on and the system should turn on and pressurize the outlet tubing to the set point

of the pressure switch and turn off

11. Have someone use the gun and monitor the system to make sure that the pump is not cycling un-

necessarily. If it is turning on an off rapidly address one of the three below issues.