Optimizing the System

Consistently achieve the desired cleaning and presentation/performance

using the least amount of chemical and water


Injectors vs. Metering Tips vs. Nozzles

The key to optimizing the system is through trial and error.

Don’t be afraid to try these steps to achieve your ideal performance.

What do injectors do?

o

Increases or decreases the amount of water

in the solution

What do metering tips do?

o

Increases or decreases the amount of

chemical in the solution

What do nozzles do?

o

Determines the pattern and backpressure of

the solution


Application Optimization (repeat for each application)

View Performance at Gun with Decision Maker

• Application too wet

o

Increase air

o

Reduce injector size (decreases water)

o

Increase metering tip (increases chemical)

• Application too dry

o

Decrease air

o

Increase injector size (increases water)

o

Decrease metering tip (decreases chemical)

• Nozzle sputters

o

Decrease air

o

Decrease nozzle(s) and/or size used on arch

o

Increase injector size (increases water)

• Too much chemical used

o

Decrease metering tip

o

Decrease metering tip and injector size (to maintain desired ratio)

• No chemical

o

Check vacuum of injector (see instructions on page 9)

o

Check foot valve

o

Check metering tip

• Nozzle fan pattern not filled

o

Reduce nozzle size

o

Increase injector size (increases water)

• Water not present at all nozzles on arch

o

Verify check valves are functioning

o

Verify nozzles are not plugged

o

Reduce number of nozzles

o

Reduce nozzle size

o

Increase injector size (increases water)