Metal – Hydrotech 12301_12302_12303 Series ADVANCED REVERSE OSMOSIS WATER TREATMENT SYSTEMS User Manual

Page 10

Advertising
background image

6

METAL

PRODUCT WATER FAUCET INSTALLATION AND SYSTEM CONNECTIONS

Install faucet on flat surface at least 2" in diameter. Unused 1 1/4" hole is ideal.

Steps unique to a specific configuration are so noted. All other steps are common to either configuration.


New Faucet Installation

Refer to Faucet Site Preparation, Page 5.

Replacement Faucet Installation

Verify size of existing hole is 1 1/4".

NOTE: Item callouts refer to Page 7, Figure 7 unless
noted otherwise.

1. Air Gap Only: Verify faucet body, metal base

washer, and rubber base washer are in place above
sink (Items 1, 3, and 2).

Non-Air Gap Only: Verify faucet body, rubber body
washer, metal base washer, and rubber base washer
are in place above sink (Items 1, 9, 3, and 2).

2. CAUTION: Flow Restrictor (FLR) is installed inside

the 1/4” red tubing at the end connected to the

module. DO NOT TRIM THE END OF THE 1/4" FLR
RED TUBING (END WITH FLR LABEL)
CONNECTED TO MODULE (See Figure 10.A/B).

Air Gap Only: Install 3/8” x 48” red tubing from

Installation Kit onto larger hose barb as shown in

Figure

7.

3. Air Gap Only: Connect the 1/4” FLR red tubing

between the module and the faucet:

a.

Air Gap Only: Insert the 3/8” red tube into the
mounting hole.

a.

Air Gap Only: Insert the 1/4" FLR red tubing

upwards through mounting hole.

b.

Air Gap Only: Position module in desired
location. Trim end of FLR tubing without label to
desired length. Attach FLR tubing onto smaller
hose barb as shown in Figure 7.

4. Lower faucet into mounting hole and place

faucet over hole.

5. Air Gap Only: Install slotted washer, spacer, faucet

washer, and nut onto faucet nipple below sink and
snug them up (Items 4, 5, 6, and 7). Be sure to
properly align faucet before tightening. Do not over
tighten.

Non-Air Gap Only: Install locating washer, faucet
washer, and nut (Items 4A, 6, and 7) onto faucet
nipple below sink and snug them up. Be sure to align
faucet properly before tightening. Do not over tighten.


6. Install faucet connector (Item 8), packaged with

faucet, onto faucet nipple. Install 3/8” blue tube into
faucet connector.


7. Trim 3/8” blue tube to desired length. Install 3/8” blue

tube into 3/8” swivel elbow located on rear of module.


8. CAUTION: Red 3/8" tube connecting product water

faucet to drain saddle must run vertically (or as

closely as possible) with no sharp bends or loops

(See Page 4, Figure 4).

Connect loose ends of tubing as follows:

a.

Non-Air Gap Only: Connect 1/4" FLR red tubing

to 1/4" male connector on drain saddle.

b.

Air Gap Only: Connect 3/8” red tubing to

3/8" male connector on drain saddle.

Storage Tank Connection - Polymer Tank Assembly

NOTE: The following Instructions refer to Page III,
Figure 1.B., Item 1.

1. CAUTION: Do not over tighten ball valve as this may

strip threads or compromise the “O” ring seal.

Hand-tighten the ball valve onto the RO storage tank.


2. Slide compression nut over 3/8” white tubing.

3. Push 3/8” white tubing into the ball valve as far as

possible.


4. While holding 3/8” white tubing in the ball valve,

hand-tighten the compression nut onto the ball valve.


5. The basic installation is complete and system is ready

for activation (See Page 12).


Storage Tank Connection - Metal Tank Assembly

NOTE: The following instructions refer to Page III,
Figure 1.B., Item 2.

NOTE: Refer to Page 2, Inter-Component Connections
for instructions on how to install tubing.

1. Install ball valve (located inside of storage tank
box) onto the 1/4” storage tank nipple. Use thread
sealing tape (P/N 35700002) to seal threads between
ball valve and nipple.

2. Connect 3/8” white tubing between module and

storage tank shut-off valve.


3. The basic installation is complete and system is ready

for activation (see Page 12).


Advertising