ACTIVATING THE SYSTEM

CAUTION: Make sure all water supply lines, drain lines, and fittings are secure and free from leakage.


NOTE: Item callouts refer to Page 10, Figure 10.A, and
Page 11, Figure 10.B.

1

. Open source water supply valve. Close product water

faucet. Check for leakage.


2. Turn tank valve one-quarter turn counter- clockwise to

open valve (handle should be in line with tubing as it
enters connection).


3. Confirm system is producing water. Module will be

sending rinse water to drain.


Optional Smartap

Water Quality Monitor

Perform Steps 4 - 7

4.

CAUTION: Wiring within module cover connects

monitor components. If wires, circuit board, or

connections are damaged and/or wetted, monitor will

not function.

Loosen mounting bracket screws (Item 3). Gently pull
manifold cover (Item 27 - Push Button Monitor) up and
away from the manifold body.


5.

CAUTION: Verify battery connector alignment

before making connection (Page 14, Figure 11).

CAUTION:

Connect battery to monitor after system

has been in production mode for at least 5 minutes.

This ensures sensing switch is in proper position to

record

data.

Connect battery (Item 28) on manifold by pressing clip
onto battery terminals (Figure 11).

6. Replace manifold cover and tighten screws.

7. Test battery connection by activating monitor. Press

push button. If either indicator light illuminates,
connection is good.

NOTE: Release button or close faucet immediately

after light illuminates. Test is to confirm battery

connection, not water quality.


8. Open product water faucet and let water flow until all air

has been expelled from system. Lock faucet by rotating

the handle 90° or by lifting handle, as applicable.

9. Close product water faucet. In 30 minutes, check

connections for leaks and correct if necessary.

Icemaker/Extra point of use: Check connections on
these supply lines for leaks.


10 Allow storage tank to fill overnight.

11

WARNING: DO NOT USE THE FIRST FULL

STORAGE TANK OF WATER

Discard (to drain) first full tank of water by opening
product water (and extra point-of-use) faucet until water
flow stops, then close faucet. This will flush sanitizing
solution from system.

Icemaker: Let tray/bin fill with ice cubes. Discard all
ice cubes. This flushes sanitizing solution from lines to
icemaker.


12. System is ready to use. Should there be any aftertaste

or odor to water or ice cubes, repeat Steps 10 and 11.

DO NOT USE THE FIRST STORAGE TANK OF WATER

Allow storage tank to fill overnight. Dispense this water to drain.

This process removes factory-installed sanitizing solution from the entire system and sends it to drain.

This process also sanitizes fittings and tubing used during installation.

MAINTENANCE PROCEDURE PREPARATION

RECOMMENDATIONS

HAVE ALL EQUIPMENT AND REPLACEMENT COMPONENTS ON HAND AND READY BEFORE BEGINNING PROCEDURE.

A CLEAN WORK AREA AND EQUIPMENT ARE ESSENTIAL TO PROPERLY CLEAN AND/OR SANITIZE THE SYSTEM.

(i.e., CLEAN HANDS, TOOLS, WORK SURFACE, AND CONTAINERS)

EQUIPMENT NEEDED

Safety glasses

Rubber gloves, sanitary

Wash Cloth, Clean and Lint-free

Liquid dish soap

Household bleach - Unscented Only

(5 1/4% sodium hypo chlorite)

Plastic storage bag

Manual Air Pump

Plastic bucket

Plastic bowl

“O” ring Lube FDA Approved

(P/N 30300026)