Start-up sequence, Before using the unit – Hydrotech DLR-AP Ultraviolet Water Disinfection Unit User Manual

Page 13

Advertising
background image

Start-Up Sequence


Before using
the unit…

Follow the start-up procedures below.

If your unit has… Then…

No solenoid valve
installed

• Slowly fill the unit with water.

• Plug power cord into wall outlet.

Within the first five seconds, press and hold the RESET button for 5 seconds

to set internal "Days" counter to 365. The alarm buzzer will beep three times
and all LEDs will blink three times to indicate that the unit has been reset.

• Wait 30 seconds. If the lamp is working, the "Lamp On" LED will light and the

internal "Days" counter will begin counting down.

• Turn off water flow.

• Sanitize your system before using your household water (see maintenance

section for instructions. Slowly fill the unit with water.

Optional solenoid
valve installed

With the optional solenoid valve installed, a temporary water flow path must be
provided for the first five minutes.
• Slowly fill the unit with water.

• Plug power cord into wall outlet.

Within the first five seconds, press and hold the RESET button for 5 seconds

to set internal "Days" counter to 365. The alarm buzzer will beep three times
and all LEDs will blink three times to indicate that the unit has been reset.

• Wait 30 seconds. If the lamp is working, the "Lamp On" LED will light and the

internal "Days" counter will begin counting down.

• Turn off water flow.

• Sanitize your water system before using the disinfection unit (see maintenance

section for instructions).