Alarms, Displays, Alarm activation – Hydrotech DLR-AP Ultraviolet Water Disinfection Unit User Manual

Page 19: Cause

Advertising
background image

Alarms


Displays

The front panel of the electrical control box has the following LED displays:

LED Displays

Diagram


• LAMP ON: green

• REPLACE LAMP: red

• ALARM: red













Alarm
activation




The WEDECO UV disinfection unit has built in alarms to warn of inefficient
performance or lamp failure.

Model

What Happens

Cause

How to Resolve

DLR-AP



• The REPLACE LAMP

LED blinks.

• The internal ALARM

beeps once every 5
minutes.






The internal counter has reached 30
days of lamp life remaining.



IMPORTANT! Water to the
house is being disinfected and
the solenoid valve will remain
open.

• Press the RESET button once to

silence the alarm buzzer for 5 days.
The alarm buzzer will begin to beep
again 5 days after pressing the
RESET button and continue until
lamp has been replaced and the unit
reset.

• Replace UV lamp within 30 days to

ensure optimum performance from the
unit.

DLR-AP

• The LAMP ON LED is

no longer illuminated.

• The REPLACE LAMP

LED is illuminated
continuously.

• The ALARM LED

blinks

• The internal ALARM

buzzer beeps
continuously.


The internal counter has reached 0
(zero) days of lamp life. Or, lamp has
failed due to another problem. (See
Troubleshooting section.)



WARNING! Disinfection may
be insufficient to ensure safe
drinking water.

• Press the RESET button once to

silence the alarm buzzer for 5 days.
The alarm buzzer will begin to beep
again 5 days after pressing the
RESET button and continue until
lamp has been replaced and the unit
reset.

• Replace lamp immediately. Follow

instructions on lamp replacement in
the manual.

STATUS

ALARM

LAMP ON

REPLACE LAMP

19