Installing the uv lamp, Caution, Insert lamp in chamber – Hydrotech DLR-AP Ultraviolet Water Disinfection Unit User Manual

Page 10: Installing the uv lamp -10

Advertising
background image

Installing the UV Lamp

CAUTION

UV lamp is very fragile. Do not handle it with bare hands. Use clean cotton
gloves or cloth
when handling lamp to keep it free of dust or fingerprints. If
dust or fingerprints get on the lamp, wipe it with a clean cloth and alcohol.


Insert lamp in
chamber


Follow these steps to install the UV lamp in the disinfection chamber.

Step Action

1

Insert the lamp into the headpiece. Gently pinch the two large tabs on the
transparent lamp clip and push until the tab locks into the groove (see step 2).

















2

Make sure that the transparent tab is properly snapped into the headpiece and is
not pushed down too far.

















HEAD PIECE

DISINFECTION
CHAMBER

GROOVE

HORIZONTAL TAB

LOCATED IN GROOVE

TAB PROPERLY

TAB NOT PROPERLY
LOCATED IN GROOVE

TRANSPARENT
LAMP CLIP


10

Advertising
This manual is related to the following products: