Installing the UV Lamp
CAUTION
UV lamp is very fragile. Do not handle it with bare hands. Use clean cotton
gloves or cloth
when handling lamp to keep it free of dust or fingerprints. If
dust or fingerprints get on the lamp, wipe it with a clean cloth and alcohol.
Insert lamp in
chamber
Follow these steps to install the UV lamp in the disinfection chamber.
Step
Action
1
Insert the lamp into the headpiece. Gently pinch the two large tabs on the
transparent lamp clip and push until the tab locks into the groove (see step 2).
2
Make sure that the transparent tab is properly snapped into the headpiece and is
not pushed down too far.
HEAD PIECE
DISINFECTION
CHAMBER
GROOVE
HORIZONTAL TAB
LOCATED IN GROOVE
TAB PROPERLY
TAB NOT PROPERLY
LOCATED IN GROOVE
TRANSPARENT
LAMP CLIP