Troubleshooting – Hydrotech DLR-A Ultraviolet Water Disinfection Unit User Manual

Page 21

Advertising
background image

Troubleshooting

Determining
problem

The troubleshooting guide gives you suggestions for resolving problems.


If…

Then…

The unit is leaking water

x Ensure that the headpiece is tight.
x Verify that inlet water pressure is not >125 psi.
x Ensure that headpiece O-ring is seated properly.
x Lubricate O-ring (use food-grade silicone).
x Check O-ring for cracks or rips. Replace if necessary.
x Check quartz sleeve for possible cracks. If sleeve is cracked, call distributor for

replacement.

Glo-Cap is not lit or has
gone out

x Verify that all electrical connections are correct.
x Replace lamp. If problem is solved, resume unit operation.
x If lamp still does not light, electrical control box may need to be replaced. Call distributor

for replacement information.

Poor bacterial
performance

x Replace lamp if it is more than 365 days old or nearing the end of its lamp life.
x Perform routine maintenance.
x Check water quality. If water quality has changed then you may need to install filters or

other disinfection units to ensure that water supply does not exceed recommended
maximum concentration levels (shown in Step 1 of Pre-Installation Instructions).

x Verify flow rate using the flow rate table found in the Technical Specifications at the back

of the manual.

Power fails

x The unit will restart automatically.

Note

: The unit is designed for continuous operation. Never connect the unit to a timer or other

device, which will cause the unit to cycle on and off. Excessive cycling of the power will
reduce lamp life.

Display screen is blank

x Ensure that the unit is assembled and installed correctly. In the case of improper handling

or assembly during installation and/or servicing, the unit will turn off power to the lamp
and display a blank screen.

x

Check for damage to the lamp filament elements, quartz sleeve, or electrode connectors.
Applying power to a unit with such damage will cause a blank display screen. Damage
may be caused from shipping, overheating the lamp by operating the unit with no water in
the chamber, introducing debris into the unit from the water source, or improper handling
or assembly during service or installation.

Note

: In most cases, replacing the lamp, and/or quartz sleeve will return the unit to proper

operation. If the unit fails to resume operation, notify your distributor.

Unit gives faulty alarms

x The ballast or control circuit may be faulty. Call distributor for replacement information.

20