5.5.2 Configuring Relay outputs

To configure the Control I/O for Relay outputs:

1. In Menu mode [ ], select Control I/O.

2. From the second menu (second display screen), select Outputs.

3. From the third menu (third display screen), select one of the four available Relay outputs:

Relay 1

Relay 2

Relay 3

Relay 4

4. From the fourth menu (fourth display screen), select one of the following:

None

Call Key 1

Talk Key 1

Call Key 2

Talk Key 2

Call Key 3

Talk Key 3

Call Key 4

Talk Key 4

SA Key

Note:

The number of the key relates to the keyset to which it belongs (for example, Call Key 1 is the
Call key for the first keyset / display screen).

The default setting is None.

5. To enable (confirm) the selected setting, press the rotary control [ ].

5.6 Configuring Module Settings

Up to three optional interface modules (of the same or different types) can be fitted to the expansion bay
of the HMS-4X Main Station.

Warning:

The interface modules are not hot pluggable. Ensure that the Main Station is powered down

before inserting or removing modules.

The Menu mode [ ] > Module Settings are used to set up the devices connected to the interface
modules.

Tip:

For more detailed information about interface modules, including pin out information, see:

2.2.1 HMS-4X Main Station rear panel: Interface modules.