Beeper behavior, Led behavior during setup, Factory reset – INSTEON Mini Remote Switch 2342-242/2444A3WH, 2342-442, 2342-542 Manual User Manual

Page 11

Advertising
background image

Page 11 of 16

2342-242/2444A3, 2342-442, 2342-542 Rev: 1/21/2014 7:24 AM

Beeper Behavior

Command

Method

Beeper Disabled

(Default)

Beeper Enabled

On

Tap

-

Single Beep

Off

Tap

-

Single Beep

Fast-On

Double-Tap

-

Single Beep

Fast-Off

Double-Tap

-

Single Beep

Begin Bright

Press & hold

-

Single Beep

Begin Dim

Press & hold

-

Single Beep

Setup Action

Beeper

Enter Setup Mode, Transition to next setup mode or Exit
Setup Mode

Single Beep

Setup successful, return to Ready Mode

Double-Beep

Return to Ready Mode after a longer than 3 minute time-
out

Long Beep (3 seconds)

Failure to add a scene responder

Long Beep (3 seconds)

Exiting Stuck Button

Long Beep (3 seconds)

LED Behavior during Setup

Mini Remote has a two-color LED (Green & Red) which displays helpful information.

LED State

Meaning

Blinking Green slowly

Add Responder Setup Mode, or

LED on/off Setup Mode

Blinking Red slowly

Remove Responder Setup Mode

Double-Blinking Green slowly

Multi-Add Responder Setup Mode, or

Beeper on/off Setup Mode

Double-Blinking Red slowly

Multi-Remove Responder Setup Mode, or

Keypad Configuration Setup Mode

Factory Reset

The factory reset procedure clears all settings from Mini Remote including INSTEON scenes.

1) If possible, unlink (remove) all scene responders prior to performing factory reset

2) Turn Mini Remote off (slide power switch to left)

3) Press & Hold Set Button

4) While continuing to hold the Set Button, turn Mini Remote back on (slide power switch to the right)

Mini Remote will beep and its LED stays solid green

Mini Remote will emit a long beep