Cautions and Warnings

CAUTIONS AND WARNINGS

Read and understand these instructions before installing and retain them for future reference.

This product is intended for installation in accordance with the National Electric Code and local regulations in the United States or
the Canadian Electrical Code and local regulations in Canada. Use indoors only. This product is not designed or approved for
use on power lines other than single-phase voltages between 100V and 277V, 50/60Hz. Attempting to use this product on non-
approved powerlines may have hazardous consequences.

Recommended installation practices:

Use only indoors or in an outdoor-rated box.

Be sure that you have turned off the circuit breaker or removed the fuse for the circuit into which you are installing this
product. Installing this product with the power on will expose you to dangerous voltages.

The wires connecting SwitchLinc to the incoming power must be protected by a fuse or circuit breaker of 20A or less.

Connect using only copper or copper-clad wire.

This product may feel warm during operation. The amount of heat generated is within approved limits and poses no
hazards. To minimize heat buildup, ensure the area surrounding the rear of this product is as clear of clutter as possible.

To reduce the risk of overheating and possible damage to other equipment, do not use this product to control loads in
excess of the specified maximum(s) or install in locations with electricity specifications which are outside of the product’s
specifications. If this device supports dimming, please note that dimming an inductive load—such as a fan or transformer—
could damage the dimmer, the load-bearing device or both. If the manufacturer of the load-bearing device does not
recommend dimming, use a non-dimming INSTEON on/off switch. USER ASSUMES ALL RISKS ASSOCIATED WITH
DIMMING AN INDUCTIVE LOAD.

Identifying the Electrical Wires in Your Home

Line – usually black, may also be called Hot, Live or Power, carries 100-277VAC electricity into the wall box.

Neutral – usually a white wire bundle, commonly daisy-chained from box to box.

Load – usually black, from a separate cable jacket.

Ground – Bare copper wire or metal fixture (if grounded).


If installing in a commercial application, please follow standard commercial wiring practices.

IMPORTANT!

Each INSTEON product is assigned a unique INSTEON I.D., which is printed on the product’s label. Please take note of
each product’s I.D. for future reference.

If you have any difficulties or questions, consult an electrician. If you are not knowledgeable about or comfortable with
electrical circuitry, have a qualified electrician install the product for you.

Tools Needed

Flathead screwdriver

Phillips screwdriver

Wire cutter/stripper

Voltage meter











Advertising