Troubleshooting – INSTEON DIN Rail Dimmer - 2452-222 (US), 2452-422 (EU), 2452-522 (AUS/NZ) Manual User Manual

Page 15

Advertising
background image

Page 15 of 19

2452-222/2452-422/2452-522 - Rev: 1/21/2014 7:50 AM

Troubleshooting

Problem

Possible Cause

Solution

The LED on DIN Rail is
not turning on at all and
won't control my light

DIN Rail is not getting power

Make sure the circuit breaker is turned on

Check junction box wires to ensure all connections are
tight and no bare wires are exposed

Check the light fixture to ensure all connections are tight
and no bare wires are exposed

Check fuse to ensure it is not broken.

The switch I'm replacing
only has two wires

DIN Rail needs a Neutral wire
in order to operate

Look in the rear of the box for a group of wires all tied
together with a wire nut. Those are the Neutral wires.

Pull a Neutral from nearby junction box

DIN Rail is not receiving
signals from a controller

DIN Rail and the controller
are not within range of each
other

Install additional INSTEON devices to strengthen
INSTEON signals

US applications: Add a Range Extender

Move controller within range of DIN Rail

The controller is plugged into
a power strip

Power line signals can't travel through some power filters.
Plugging the controller directly into a wall outlet works
best.

Other appliance(s) are
causing line noise

Install filters where device(s) are causing line noise

Install additional INSTEON devices to strengthen
INSTEON signals

The load turned on by
itself

Another controller, a timer, or
stray X10 signals triggered
DIN Rail

Install a power line signal blocker in your home to keep
X10 signals from neighboring homes from interfering.
Consider not using DIN Rail in X10 mode.

DIN Rail may have an
undesired responder
membership

Use software to remove membership or perform a factory
reset

The controlled load does
not appear to turn on or
off right away

Responder scene ramp rate
might be quite slow

Set a faster ramp rate – software recommended

DIN Rail responds to on
commands but not off
commands

Load connected to DIN Rail is
producing electrical noise that
is interfering with DIN Rail
reception of power line signal

Install an in-line noise filter between the load and DIN Rail

Install additional INSTEON devices to strengthen
INSTEON signals

My load only will turn off
when I tap a button on
DIN Rail, but I can
brighten and dim it

The on-level may be set to
fully-off or very dim

Set a brighter on-level. See

Local On-Level

When I try to turn on my
load with another
controller, the load will
turn on, then back off

DIN Rail may be set up with
an INSTEON on-level at a
high brightness and an X10
Primary or scene address on-
Level at a low brightness

Remove the X10 address

Remove the X10 address from the INSTEON controller

When I press a button on DIN Rail is trying to control a Connect power to the device

Advertising