INTELLINET NETWORK 515566 Net Toner and Probe Kit User Manual

Page 6

Advertising
background image

6

• Red indicates reversed polarity.

• Flickering red and green indicates the presence of AC power or a

ringing line.

• A faint LED indicates a busy or faulted line.
Verifying the Line
1. Flip the toggle switch to the OFF/Polarity position.

2. Connect the black lead to the Tip (+) connection (usually green or

blue); connect the red lead to the Ring (–) connection (usually red or

labeled “R”). Or insert the 4-pin modular cable into the wall jack, or

plug the line into RJ45 jack on the Net Toner.

3. Dial the line to be verified. If the tester is connected to the correct line,

the Line 1 LED will flicker green and red.

4. Monitor the line and flip the toggle switch to the Continuity position.

This will terminate the call to confirm the identification.
Net Probe — Tone Tracing
1. Set the TEL/TRACE selector to the TRACE (down) position.

2. Push the TRACE button to make the probe end active.

3. Hold the TRACE button down to trace a line, or plug the tracer’s RJ45

jack into a wall outlet using a jumper cable, or connect the clip leads

to test pins.
Tracing for unknown cable path/termination – Adjust the gain (volume)

control to the desired level. Begin tracing from the tone generator. Slowly

maneuver the tone tracer away from the source, taking caution to avoid

any high-voltage sources. Adjust the gain control whenever necessary

to maintain constant (or regain) audio contact with the tone from the

tone generator. Trace over the entire path of the test cable or until the

cable end is located.
Locating termination verification/general area of termination – Adjust the

gain (volume) control to the maximum level. Begin tracing in the general

area of the cable termination. Slowly maneuver the tone tracer in a zig-

zagging fashion carefully and methodically over the entire area until the

generated tone is found. Take caution to avoid any high-voltage sources.

6