7430 series, Installation instructions, Inductive slot sensor-electrical specifications – KING 7430 Series PVC_PVDF User Manual

Page 4: Inductive ring sensor, Switch isolator, Fiber optic sensor, Fiber optic sensor-electrical specifications

Advertising
background image

(714) 891-0008 • www.kinginstrumentco.com

When it comes to flow...we’re instrumental.

4

Installation Instructions

Installation Instructions

7430 series asseMbly with inDuCtiVe
ring sensor Parts list:

1. Top Frame Plug
2. Frame Assembly
3. Glass Meter Tube Assembly
4. Inductive Ring Sensor
5. Sensor Tension Spring
6. Alarm Junction Box
7. Alarm Junction Box Screw
8. Strain Connector
9. Shield

7430 series inDuCtiVe ring sensor

INDUCTIVE RING SENSOR:

All 7430 Series flowmeters may be fitted with one inductive ring sensor.
The inductive ring sensor is mounted on the glass meter tube using
springs to put tension between the frame and glass meter tube.
The sensor can be either proximity or latching type and can only be
used with 316SS or Carboloy floats. The inductive ring sensor produces
an electromagnetic field that senses the metal float within sensing
zone.
Inductive ring sensors are 2-wire, DC, low current devices and are de-
signed to be used with a remote intrinsic safety barrier / switch isolator.

SWITCH ISOLATOR:

Inductive ring sensors are designed to be connected to a switch isolator
for intrinsically safe applications. The purpose of the switch isolator is
to supplyelectrical signals between safe and hazardous areas in either
direction while limiting the amount of energy that can be transferred
even under fault conditions. Switch isolators are available with 220VAC,
110VAC or 24VDC supply voltage requirements, contain single pole
double throw (SPDT) relays, and are DIN rail mountable. See switch
isolator specifications for electrical connections and further details.

inDuCtiVe ring sensor-eleCtriCal
sPeCiFiCations

TYPE:

INDUCTIVE PROxIMITY OR

LATCHING
SUPPLY VOLTAGE:

5-25V DC (Switch Isolator)

OUTPUT: NAMUR
OUTPUT LOAD CURRENT:

<= 1mA-Float Present

>= 3mA (15mA Max.)-Float Absent

SWITCHING FREQUENCY: 2kHZ
HOUSING RATING:

IP67

OPERATING TEMPERATURE: -13°F to 104°F

1/8” Latching

-13°F to 158°F

1/8” Proximity

1/4” Latching

1/4” Proximity

WIRING:

PVC covered, 2 Conductor, 26

AWG, 6.5 Ft. Long. Brown (+) / Blue (-)

PEPPERL+FUCHS

UL:

General Purpose

SENSOR APPROVALS

FM:

Intrinsically Safe

CSA:

Intrinsically Safe

CENELEC: Intrinsically Safe

12700 Pala Drive, Garden Grove, CA 92841

www.kinginstrumentco.com / (714) 891-0008

Meters are warranted against defects in materials and workmanship

to the original user for a period of thirteen (13) months from the date

of factory shipment, provided the meter is installed, operated and

maintained in accordance with King Instrument Company's

instructions and recommendations.

This warranty does not apply if failure is caused or contributed to by

any of the following: improper handling, improper storage, abuse,

unsuitable application of the product, lack of reasonable and

necessary maintenance, use exceeding suggested pressure and

temperature maximums, improper packaging for return, or repairs

made or attempted to be made by anyone other than King Instrument

Company, Inc.

KING INSTRUMENT COMPANY, INC. MAKES NO

WARRANTY AS TO THE FITNESS OF ITS PRODUCTS

FOR SPECIFIC APPLICATIONS.

This warranty is valid for the original end-user only and does not

apply to products that have been damaged or modified. This

warranty is non-transferrable and is limited to replacement or repair.

The liability of King Instrument Company arising out of its supply of

the products, or their use, shall not in any case exceed the cost of

correcting defects in the products as set forth above.

THIS WARRANTY IS A LIMITED WARRANTY AND

SHALL BE IN LIEU OF ANY OTHER WARRANTIES,

EXPRESSED OR IMPLIED, INCLUDING BUT NOT

LIMITED TO ANY IMPLIED WARRANTY OR

MERCHANTABILITY OR FITNESS FOR A PARTICULAR

PURPOSE. THERE ARE NO OTHER WARRANTIES

WHICH EXIST BEYOND THE DESCRIPTION OR FACE

HEREOF.

IN NO EVENT SHALL KING INSTRUMENT COMPANY BE

LIABLE FOR LOSS OF PROFITS, INDIRECT,

CONSEQUENTIAL OR INCIDENTAL DAMAGES.

Products should be returned, prepaid, to King Instrument Company,

Inc. with proof of purchase. Call factory for Return Merchandise

Authorization (RMA) number and return instructions.

2013A

All 7430 Series flowmeters may be fitted with one inductive ring sensor.

INDUCTIVE SLOT SENSOR-ELECTRICAL SPECIFICATIONS

TYPE:
SUPPLY VOLTAGE:
OUTPUT:
OUTPUT LOAD CURRENT:

Inductive Proximity or Latching

5-25V DC (Switch Isolator)

NAMUR
<= 1mA-Float Present

>= 3mA (15mA Max.)-Float Absent

SWITCHING FREQUENCY:

2kHZ

HOUSING RATING:

IP67

WIRING:

PVC covered, 2 Conductor, 26

AWG, 6.5 Ft. Long.

Brown (+) / Blue (-)

PEPPERL+FUCHS

General Purpose

Intrinsically Safe

UL:

FM:

SENSOR APPROVALS:

INDUCTIVE RING SENSOR:

The inductive ring sensor is mounted on the glass meter tube using springs to

put tension between the frame and glass meter tube.

The sensor can be either proximity or latching type and can only be used with

316SS or Carboloy floats. The inductive ring sensor produces an

electromagnetic field that senses the metal float within sensing zone.

Inductive ring sensors are 2-wire, DC, low current devices and are designed to

be used with a remote intrinsic safety barrier / switch isolator.

SWITCH ISOLATOR:

Inductive ring sensors are designed to be connected to a switch isolator for

intrinsically safe applications. The purpose of the switch isolator is to supply

electrical signals between safe and hazardous areas in either direction while

limiting the amount of energy that can be transferred even under fault

conditions. Switch isolators are available with 220VAC, 110VAC or 24VDC

supply voltage requirements, contain single pole double throw (SPDT) relays,

and are DIN rail mountable. See switch isolator specifications for electrical

connections and further details.

Intrinsically Safe

CSA:

Intrinsically Safe

CENELEC:

All 7430 Series flowmeters may be fitted with one fiber optic sensor.

FIBER OPTIC SENSOR:

The fiber optic sensor is mounted to the frame with a screw in a slotted screw

for adjustability. The sensor uses a pair of fiber optic cables with an emitter and

receiver to transmit the light generated by the sensor. The sensor can interface

directly to a Programmable Logic Controller (PLC) or when connected to a

separate relay can trigger a local or remote alarm.

FIBER OPTIC SENSOR-ELECTRICAL SPECIFICATIONS

SUPPLY VOLTAGE:

OUTPUT:

OUTPUT RATING:

10-30V DC

NPN Sinking, N.O. & N.C.

150mA max. Total Load

OUTPUT RESPONSE TIME:

1ms

HOUSING RATING:

IP67; NEMA 6

SUPPLY CURRENT:

25mA

PNP Sourcing, N.O. & N.C.

OFF STATE LEAKAGE CURRENT:

1 MICOAMP @ 30V DC

OUTPUT SATURATION VOLTAGE:

<=1V at 10mA DC

>=1.5V at 150mA DC

REPEATABILITY:

0.25ms

OPERATING TEMPERATURE:

-5°F TO +131°F

TOP FRAME PLUG

FRAME ASSEMBLY

GLASS METER TUBE ASSEMBLY

FIBER OPTIC HOUSING SCREW

FIBER OPTIC HOUSING

ALARM JUNCTION BOX SCREW

STRAIN CONNECTOR

FIBER OPTIC CABLE

FIBER OPTIC ADAPTOR

FIBER OPTIC SENSOR

SHIELD

TOP FRAME PLUG

FRAME ASSEMBLY

GLASS METER TUBE ASSEMBLY

INDUCTIVE RING SENSOR

SENSOR TENSION SPRING

ALARM JUNCTION BOX SCREW

STRAIN CONNECTOR

SHIELD

ALARM JUNCTION BOX

2X

OPERATING TEMPERATURE:

-13°F to 158°F

ALARM JUNCTION BOX

7430 Series

PVC/PVDF

Advertising