Above ground filter installation – King Technology Prevail System User Manual

Page 11

Advertising
background image

Above Ground Filter Installation

Apply pipe thread tape or
sealant to each threaded end
of nipple.

Screw one end of nipple
into the filter return.

Screw either side of
Cycler on to open nipple
end until upright and
secure.

Tighten turning 1 to 2
revolutions with wrench.
DO NOT OVER TIGHTEN.

HOSE

ADAPTER

HOSE

ADAPTER

HOSE ADAPTER

11

Bi-flow valve
design allows
water flow in
either
direction.

4.

6.

1.

2.

3.

7.

MATERIALS NEEDED:

One
Hose
Clamp

Corrosion Resistant
Check Valve

RECOMMENDED:

INCLUDED
WITH CYCLER:

Screw adapter into the
other side of Cycler.Hand

tighten. Finish tightening by
turning 1 to 2 revolutions
with wrench.
DO NOT OVER TIGHTEN.

Apply pipe thread
tape or sealant to
threaded end of hose
adapter.

Attach return section of hose
to the adapter with clamp.
Tighten clamp with
screwdriver.

TOOLS NEEDED:

Screwdriver

When using a Chlorine Pac,
installing a corrosion resistant
check valve is
recommended.

One Hose Adapter
1 1/2" X 1 1/2" X 1 1/4"

One 6" X 1 1/2" TBE

PVC Nipple

One Section of
1 1/2" Flex Hose
(provided with filter)

Pipe Wrench

Pipe Thread Tape

or Sealant

5.

Advertising