1.5 E

NVIRONMENTAL

R

EQUIREMENTS

Requirement

Description

Enclosure IP20

NEMA 1

Operating temperature

0 to 55 degrees C

32 to 132 degrees F

Humidity Non-condensing

85% at 55 degrees C

85% at 132 degrees F

Altitude 1000

meters

3300 feet

Atmosphere

Non-flammable, non-corrosive and dust free

Storage temperature range

-25 to 80 degrees C

-13 to 176 degrees F

Transport temperature range

-25 to 80 degrees C

-13 to 176 degrees F

1.6 EMC

T

ECHNICAL

R

ATINGS

Port

Phenomenon

Test Standard

Level

Test Standard

Enclosure

ESD

EN 61000-4-2

8KV AD, 1KV CD

EN 61326:1997

Enclosure

RF Field

EN 61000-4-3

10V/m,1 Khz AM

EN 61326:1997

Transducer Leads

Fast Transient
Burst

EN 61000-4-4

1kV

EN 61326:1997

Output Leads

Fast Transient
Burst

EN 61000-4-4

1kV

EN 61326:1997

Transducer Leads

Conducted
Immunity

EN 61000-4-6

3V/m

EN 61326:1997

Output Leads

Conducted
Immunity

EN 61000-4-6

3V/m

EN 61326:1997

** AC Power Line

Surge

EN 61000-4-5

+/-2KV L to PE

+/-1KV L to L

EN 61326:1997

** AC Power Line

Voltage Dips

EN 61000-4-11

+/-0.5 Cycle

100%

EN 61326:1997

** These specifications apply when using CMC power supply, MWI-13418.

1.7 E

MISSION SPECIFICATIONS

Port

Phenomenon

Test Standard

Level

Generic Standard

Enclosure Radiated

EN

61326:

1997

Class A

EN 61326:1997


The levels of performance indicated are achieved when the Classic Series DIN Rail Amplifier is