WebPro Unwind Brake Tension Controller


Remember to press the CONFIRM key, otherwise the parameters will not be saved to the memory.

Note Start in Control Screen
The Controller is despatched with this item set to "No". We recommend that after all commissioning is
finished that this is then set to "Yes". When the Controller is now switched on, the program is loaded, the
company logos are shown briefly and then the Control or operating screen ready for use by the operator.

Note
The Controller will not accept an invalid input value which is outside the limits of operation. If an invalid
input is attempted the Controller will revert to the previous valid input.

Language

(English, Deutsch, Français, Italiano, Español)

The default language is English. If changed, all text shown on the Controller will be changed to
that language and an extra item "5 - Translations" will be added to the Introduction screen.


Unit system

(SI (newtons), Kgf, pounds/foot, percent)

Select a unit system. All items which use units will be changed accordingly.


Unwind type

(Brake, Torque, Speed)

Select the unwind type. In Torque and Speed control modes tachos or encoders must be
available for line speed and winder (reel) speed signals.
Contact CMC Inc for the AO-70172 handbook for motor powered unwind systems.


Output range

(0-10V / 0-20mA / 4-20mA / 0-50mA)

The 0-10V has a maximum output of 2mA and the 0V common is connected to ground.
The 0-20mA / 4-20mA high is connected internally to +24V DC, maximum load 250

S

The 0-50mA is intended for the IMI Electro/Pneumatic converter type 101X.


Start in control screen

(No / Yes)

The Controller is despatched from the factory with this set to "No". We recommend that after all
commissioning and set up is finished that this is then set to "Yes". When the Controller is now
switched on, the program is loaded, the company logos are shown briefly and then the Control or
operating screen is shown ready for use by the operator.


Enable MAN / AUTO / OFF keys

(No / yes)

When using the Digital Inputs to control the sequence of the system, this item should be set to
"No" to prevent accidental operation.


Dual tension range

(No / Yes)

Select "Yes" if required. Enter two values of tension. The (normal) value must be the same value
as entered during Calibrate tension. The (low) value should not be less than one third of the
(normal) value. Terminal TB4/11 is switched OFF when LOW is selected from the front panel.