Installation, Cabinet installation, Electro-pneumatic ( e/p ) converter installation – Cleveland Motion Controls WebPro Unwind Brake Tension Controller MWP – 12662 - 0 REV BA User Manual

Page 6: High current driver ( hcd ) installation, Webpro unwind brake tension controller

Advertising
background image

AO-70173

6

Revision BA

WebPro Unwind Brake Tension Controller

Installation

The following parts are supplied:-
1. Controller, with software loaded for the application but requiring commissioning by the user.
2. Two keyhole mounting brackets.
3. Cable gland to be fitted to the rear cover and header connector kit for encoders.
4. Cabinet, if ordered.
5. Electro-pneumatic (E/P) Converter kit or High Current Driver, if ordered.
6. Manual (this document).
Transducers and cables may also be supplied to complete the system

The Controller should be installed using 'best practice' and in accordance with all relevant regulations.
The Controller must be installed in a dry, non-hazardous location. A panel cut out 8.27in (210mm) wide X
7.01in (178mm) high is required. The Controller is 3.94in (100mm) deep, additional space for the cables
is needed.

The Controller is retained by two mounting brackets. Remove the four screws securing the mounting
brackets to the Controller. Insert the Controller into the cut out in the panel. Refit the four screws, attach
the mounting brackets to the Controller and tighten the two nylon screws to retain the Controller.

Cabinet Installation

The cabinet has rear mounting holes for M8 fixing.
When the Controller is supplied as a cabinet version the
mains supply is terminated inside the cabinet on a three
way terminal block. The incoming mains cable should be
securely fastened by the gland plate cord grip.





Electro-Pneumatic ( E/P ) Converter Installation

CLEAN DRY OIL-FREE air of instrument quality, maximum supply pressure 100 PSI/7 Bar, filtered to 5
micron or better is required. The air line distance between the E/P Converter and the brake or clutch
should not exceed 5 metres or degradation of performance may occur.

High Current Driver ( HCD ) Installation

Use an HCD when the WebPro is used to drive a magnetic brake. Consult the manufacturer of the
magnetic brake for HCD recommendations. The HCD must be capable of delivering the rated brake
current and also be capable of supplying the rated brake voltage – usually 24 or 90 volts. Control of the
HCD output current must be controllable with a 0 to +10 volt signal.

CUT OUT
210 X 178

155

380

ENTRY GLAND PLATE

LOCK

6 in.

(155mm)

2 in. (50mm)

11.

8 in

(300m

m

)

8.27 in. x 7.01 in.

(210x178mm)

15 in.

(380mm)

IMI 101X converter

Fairchild TA6000-406 converter

Advertising