OPERATOR INTERFACE PRIMER

The remainder of the CX-1200 setup procedure involves setting control parameter values through the operator interface,
and then verifying system behavior using monitor parameters. The basic procedure for changing a control parameter is
first to locate the relevant parameter using the Menu, Page Up/Down and Parameter Up/Down keys, and then to modify
the parameter value using the Numeric or Scroll Up/Down keys.

The sequence for locating a control or monitor parameter using the menu driven interface is:

Press the Menu key repeatedly until the Main Menu is displayed.

Press the Parameter Up/Down keys to select the sub menu.

Press the Enter key.

Press the Parameter Up/Down keys to select the parameter category.

Press the Enter key.

Press the Page Up/Down keys, if necessary, to select the page.

Press the Parameter Up/Down keys to select the parameter.

An alternative method for locating a parameter is through the code select procedure:

Press the Code key to activate the code select line.

Enter the numeric parameter code.

Press the Enter key.

The selected parameter is now displayed on the Status screen.

For each control parameter (CP) and monitor parameter (MP) required, the menu path will be shown as:

Go to MAIN MENU\SETUP\SYSTEM SETUP\PAGE 2.
Enter RUN Mode {CP-202} = 1 = Direct Mode.

The menu selections are separated by back slashes, “\”. The parameter code is
shown in the brackets,{}.

NOTE:

The Help key accesses the Help screen and gives you a brief description of the parameter or subject that is
highlighted (active) on the screen. Press the Help key again to return to the previous screen.