Console interconnection, Rs-232 connections with external converter – CTI Products CHIB CommandSTAR Lite Host Interface Module User Manual

Page 13

Advertising
background image

CHIB Hardware Reference

Console Connections

CTI Products, Inc.

68-11662-100

9

7. Console

Interconnection

7.1

RS-232 Connections with External Converter

The CommandSTAR Lite console requires an RS-485 converter between the CHI
module and the console. The following tables show the cabling that is required
when using the CHIB module in RS-232 mode. The pinouts are based upon the
following converter:

• B&B 485CSP-2 RS-232 to RS-485 Converter

CHIB HOST

Connector DE9-

female

Signal Name

Serial
Cable

DE9-male

Dir.

Serial
Cable

DB25-male

B&B 485CSP-2 RS-

485 Converter

Signal

DCD

1

Å

8

DCD

RXD

2

Æ

2

TCD

TXD

3

Å

3

RXD

DTR

4

Å

6

DSR

Ground

5

--

7

Ground

DSR

6

Æ

20

DTR

RTS

7

Å

5

CTS

CTS

8

Æ

4

RTS

RI

9

Å

22

RI

Chassis Gnd

shell

--

shell

FG

Table 6 - RS-232 Connections CHIB to Converter Cable S2-60445

RS485 Transition Cable

CS Lite I/O Cable

B&B

Converter

Signal

B&B

Screw
Term.

Dir.

DB-25 P

DB-25 S

HD-15P

Command

STAR Lite

Signals

TDA (-)

1

Æ

15

15

13

RX-

TDB (+)

2

Æ

3

3

8

RX+

RDA (-)

3

Å

14

14

15

TX-

RDB (+)

4

Å

2

2

10

TX+

Gnd

5

--

5

5

7

Ground

Table 7 - RS-485 Connections B&B Converter to CommandSTAR Lite

Console

Advertising