CHIB Hardware Reference

Addressing

CTI Products, Inc.

68-11662-100

10

8.

MCN Addressing with CHIB Modules

Like any other module in the MCN family, the CHIB module must have a unique
address on the network.

8.1

AIB or CIB Addressing

Version 100 of the CHIB module uses a fixed address for its companion AIB or
CIB module. It always looks for that module at Group 00 : Module 0.

The AIB or CIB Module that is used with the CHIB module must be
addressed at:

Group 00

Module 0.

8.2

CHIB Address Setting (Group & Module Switches)

The CHIB module is a User Interface module in the MCN system. The MCN
System Manual and System Planner suggest that all User Interface modules be
assigned to addresses starting at Group 80. This recommendation is only for
convenience of planning your address map. The only real limitation on a CHIB
address is that it must be unique. Therefore, in a system with just an AIB (or CIB)
and a number of CHIB modules, the AIB or CIB would be addressed at 00:0 and
the CHIBs would all be set to different addresses.

Some remote applications require multiple consoles to connect to a remote AIB or
CIB using EXB modules. To ensure unique CHIB addressing in these
applications, we ship the CHIB modules pre-addressed. The addresses are unique,
and are based upon the CHIB serial number. The addresses are printed on the
Serial Number tag. The addresses start at Group:Module 00:1 and are
incremented sequentially as shown:

Serial

Number

Group

Module

1001

01

1

1002

01

2

1003

01

3

1009

01

9

1010

01

A

1011

01

B

1012

01

C

1013

01

D

1014

01

E

1015

01

F

1016

02

0

1017

02

1

If these addresses conflict with your system's address map, simply change the
CHIB addresses.