CTI Products CCU Channel Control Unit User Manual

Page 13

Advertising
background image

CCU Hardware Reference

Theory of Operation

CTI Products, Inc.

68-11843-105

7

3.4

Section 3 – Comparator A/B Select

The Comparator A/B Select section has a similar Toggle function as the
Main/Standby function.

There are three external inputs:

/Comp Toggle 1

(from Console 1)

/Comp Toggle 2

(from Console 2)

/Comp Toggle 3

(from Console 3)


There are four logic outputs:

/Comp A Select 1

(Normal)

/Comp A Select 2

(Normal)

/Comp B Select 1

(Inverted)

To Comp B Select Relay

/Comp B Select 2

(Inverted)

To Console Input


Note that each output can drive only (1) RYB-8 relay. If you need to control
multiple relays (for TX Audio, Rx Audio & COR), you will have to use one relay
to buffer the coils for the other relays.

3.5

Section 4 – RX Normal / ECS Select

The Rx Normal / ECS Select section has a similar Toggle function as the
Main/Standby function.

There are three external inputs:

/Rx Toggle 1 (from Console 1)

/Rx Toggle 2 (from Console 2)

/Rx Toggle 3 (from Console 3)


There are four logic outputs:

/Rx Normal Select 1

(Normal)

/Rx Normal Select 2

(Normal)

/Rx ECS Select 1

(Inverted)

To RX ECS Select Relay

/Rx ECS Select 2

(Inverted)

To Console Input


The RX ECS select can be used to disable the comparator repeat function. See
details in Section 2 - Repeater Control.