Internal connections, Ptt iib to otal driver pcb, Otal – CTI Products OTAL On-the-Air Driver Assembly User Manual

Page 13: River, Nternal, Onnections

Advertising
background image

CTI Products, Inc.

OTAL Driver Assembly User Guide

I

NTERNAL

C

ONNECTIONS

PTT

IIB

TO

OTAL

D

RIVER

PCB

The PTT IIB is connected to J2 on the OTAL Driver board through a ribbon cable as follows:

PTT IIB J1

IIB I/O

IIB Function

OTAL Driver PCB

Connector J2

OTAL System

Function

1

Gnd Ground

1

Ground

4

I

Link Fail Enable

7

Ground

29

I

Link Fail Invert

8

Ground

30

O

Fail 8 / Link Fail

10

LinkUp1

19

O

Rx 1

37

PTT 1B

44

O

Rx 2

38

PTT 2B

12

O

Rx 3

23

PTT 3B

37

O

Rx 4

24

PTT 4B

6

O

Rx 5

11

PTT 5B

31

O

Rx 6

12

PTT 6B

18

O

Rx 7

35

PTT 7B

26

O

Rx 8

2

PTT 8B

All signals are active low.

The Link Fail Enable and Link Fail Invert signals are inputs to the IIB. They are read-only at power-up of the
IIB. Therefore, the IIB must be connected to the OTAL Driver PCB before it is powered up. Otherwise, the
Link UP signal will not be active.