Table 5 - j1 relay contact pinout, Relay input connections -- j2, Elay – CTI Products RYB-8 Relay Board User Manual

Page 11: Nput, Onnections, 3 relay input connections -- j2

Advertising
background image

CTI Products, Inc.

MCN RYB-8 Relay Board Manual

7

68-11206-100

3.3

Relay Input Connections -- J2

The relay input connections appear on a 50-pin female micro-ribbon telco style
connector, J2. The relay input connector is laid out to match the MCN IOB
module pin-for-pin. J2 can be connected to the IOB module directly through a 25-
pair straight-through male to male cable.

Since the MCN CIB module was originally set up to match the Digitac P805
pinout, the signals are a bit scrambled. For convenience, the pinouts are as shown
in two tables, the first sorted by relay and function, and the second sorted by pin
number. The corresponding signal names for the CIB and IOB modules are also
shown.

J2

Pin

Relay

I/O Bit

Relay Board

Function

CIB

Module

Signal

IOB Mode 1 Signal

21

1

1

Input/Output

VOTE 1

Input/Output 1

22

1

2

Output

RECEIVE 1

Input 1

20

1

3

Input/Output

DISABLE 1

Input/Output 9

23

1

4

Output

FAIL 1

Input 9

46

2

1

Input/Output

VOTE 2

Input/Output 2

47

2

2

Output

RECEIVE 2

Input 2

45

2

3

Input/Output

DISABLE 2

Input/Output 10

48

2

4

Output

FAIL 2

Input 10

15

3

1

Input/Output

VOTE 3

Input/Output 3

16

3

2

Output

RECEIVE 3

Input 3

14

3

3

Input/Output

DISABLE 3

Input/Output 11

17

3

4

Output

FAIL 3

Input 11

40

4

1

Input/Output

VOTE 4

Input/Output 4

41

4

2

Output

RECEIVE 4

Input 4

39

4

3

Input/Output

DISABLE 4

Input/Output 12

42

4

4

Output

FAIL 4

Input 12

9

5

1

Input/Output

VOTE 5

Input/Output 5

10

5

2

Output

RECEIVE 5

Input 5

8

5

3

Input/Output

DISABLE 5

Input/Output 13

11

5

4

Output

FAIL 5

Input 13

34

6

1

Input/Output

VOTE 6

Input/Output 6

35

6

2

Output

RECEIVE 6

Input 6

33

6

3

Input/Output

DISABLE 6

Input/Output 14

36

6

4

Output

FAIL 6

Input 14

3

7

1

Input/Output

VOTE 7

Input/Output 7

4

7

2

Output

RECEIVE 7

Input 7

2

7

3

Input/Output

DISABLE 7

Input/Output 15

5

7

4

Output

FAIL 7

Input 15

28

8

1

Input/Output

VOTE 8

Input/Output 8

29

8

2

Output

RECEIVE 8

Input 8

27

8

3

Input/Output

DISABLE 8

Input/Output 16

30

8

4

Output

FAIL 8

Input 16

1

Common

Ground

Ground

Ground

Table 6 - Relay Inputs Connector J2 Pinout -- Sorted by Relay & Function

Advertising