3.1 Circuit Board Adjustments

SECTION 3 - ADJUSTMENTS

The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator is
complete. Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then
turned back on for the new setting to take effect.

Auto close timer (when

turned on) SW 1, switch 2.

Adjust from 1 second (full
counter clockwise) to
approximately 23 seconds
(full clockwise).

Self test (when turned

on) SW 2, switch 1.

CAUTION

Do not run self-test with the
operator connected to the gate.
The drive chain must be discon-
nected from the operator to run
the self-test. This feature is
designed for bench testing ONLY.

Dry relay contacts

(terminals 12-13) can be
set for Normally Open
(NO) or Normally Closed
(NC) operation by placing
the relay shorting bar on
the N.O. or N.C. pins
respectively.

Set the DIP-switches on the

circuit board to the desired
setting. See switch-setting
charts on next page.

1

ON

2

3

4

5

6

7

8

1

ON

2

3

4

5

6

7

8

N.O.

N.

C.

SW 1

SW 1

1

ON

2

3

4

SW 2

1

ON

2

3

4

SW 2

Loop Detector

1

23

EXIT

REVERSE

9410

Loop Detector

9410

Auto Close Timer

Self Test

DIP-Switches

Dry Relay Contact

Adjust reversing sensitivity

for OPEN and CLOSE directions.

Min

Max

OPEN

CLOSE

Min

Max

Reverse Sensors