Down loop access control device, 12 ft. arming loop, 1 ft. minimum distance – Controlled Products Systems Group 1603-080 User Manual

Page 17

Advertising
background image

1603-065-T-4-13

15

9409

4.1 Entry Lane Only

SECTION 4 - LOOP DETECTOR LANE SETUPS

Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the OFF
position. Permanent wiring must be installed to the operator as required by local electrical codes. It is recommended that a
licensed electrical contractor perform this work.

Loop detector wiring shown is for DoorKing model 9409 Dual Channel and 9410 Single Channel plug-In loop detectors only.
If using other loop detectors refer to the separate Loop Information Manual for installation instructions, loops/preformed
loops and wiring diagrams. All inputs to the main terminal are NORMALLY OPEN.

Speed Bump

Dual Channel

REVERSE
SENSITIVITY

TIME
DELAY

SW 1

SW 2

POWER

1

ON

2

3

4

5

6

7

8

1

ON

2

3

4

5

6

7

8

NC NO

UP

LOOP

DOWN

LOOP

1 2 3 4 5

6

7 8 9 10 11 12 13

14

1601

Down Loop

Access

Control

Device

Com

NO

Com

NO

A

A

12 Ft.

Arming Loop

for Access

Control Device

(Optional)

If the arming loop is not used, then a single channel loop
detector can be used (9410) in the down loop port.
Connect the
down loop to loop 1 on this detector. Connect the access control
device directly to main terminal 6 and 14.

Arming Loop Note: The arming loop only allows the access control
device to function when a vehicle is on the loop, otherwise it will not
function. This prevents pedestrians from gaining access through the
vehicular gate.

Timer Note: The timer can be used with a down loop. When timer is ON
with a down loop, it will start countdown when the arm has fully raised.
Activation of the down loop will cancel timer countdown. Useful when
an access control device has been activated but vehicle does not move
forward to activate the down loop. The arm will remain UP. Timer will
time out and lower the arm without the down loop being activated.

SW 1, switch 4 is ON.

SW 1, switch 7 is
OFF (Timer). The arm
will rotate down after
the vehicle clears the
down loop. See timer
note below.

Helps increase distance
and time between vehicles.

SW 1

1

ON

2

3

4

5

6

7

8

Main Terminal

1 Ft. Minimum Distance

Advertising
This manual is related to the following products: