2.6.1 ALARM RESET SWITCH

The gate operator is equipped with a reset switch that will silence the entrapment alarm and return
the operator to normal operation after a hard shutdown occurs. An auxiliary reset button may be
added provided that the following condition is met.

• The alarm-reset button must be located in the line of sight of the gate.
• Connect the normally open alarm-reset switch to auxiliary terminals 2 and 3.

2.6.2 AUXILIARY STOP SWITCH

This circuit creates an auxiliary stop input that will stop a moving gate when activated, or will prevent
the gate operator from starting if the switch is activated. Note that this stop input is normally open
and that a switch closure will activate the stop function. Because this is a normally open
circuit, the stop switch is not intended and should not be used as a safety interlock device.

• This circuit cannot be used if a DoorKing 3 button control station is connected to the operator.
• Place a jumper wire from terminal 13 to terminal 14.
• Connect the stop switch to terminals 14 and 20.