ACCESSORY FEATURES ON EXPANSION BOARD

ADDITIONAL FEATURES

ACCESSORY FEATURES ON EXPANSION BOARD

A

Open Input (& common)

(3-Button Control Station,

4 terminals total)

Open command - opens a closed gate.

Soft close (maintained switch does not override external safeties and does not reset alarm condition)

If maintained, pauses Timer-to-Close at OPEN limit.

Opens a closing gate and holds open an open gate.

B

Close Input (& common)

(3-Button Control Station,

4 terminals total)

Close command - closes an open gate.

Soft close (maintained switch does not override external safeties and does not reset alarm condition)

C

Stop Input (& common)

(3-PB station, 4 terminals total)

Stop command - stops a moving gate.

Hard stop (maintained switch overrides Open and Close commands and resets alarm condition)

If maintained, pauses Timer-to-Close at OPEN limit.

Overrides an Open or Close command.

D

Single Button Control, SBC

(2 terminals)

Gate command sequence - Open, Stop, Close, Stop, ...

Soft open (maintained switch does not override external safeties and does not reset alarm condition)

E

Exit Loop Input

(2 terminals)

Loop wire connection for plug-in loop detector when loop is inside secured area near gate.

Open command - opens a closed gate.

Soft open (maintained switch does not override external safeties and does not reset alarm condition)

If maintained, pauses Timer-to-Close at OPEN limit.

Opens a closing gate and holds open an open gate.

F

Shadow Loop Input

(2 terminals)

Loop wire connection for plug-in loop detector when loop is along side gate.

- Holds open gate at open

- Disregarded at Close limit and during gate motion

- Pauses Timer-to-Close at Open Limit

G

Interrupt Loop Input

(2 terminals)

Loop wire connection for plug-in loop detector when loop is positioned under gate.

- Holds open gate at open

- Stops and reverses a closing gate

- Pauses Timer-to-Close at Open Limit

H

AUX Relay #1

Normally - open and normally - closed relay contacts to control external devices,

Function of relay contact activation determined by AUX Relay #1 option switch settings. (For connection of Class

2, low voltage (<32 V), DC or AC, max 5 Amps, power sources only)

I

AUX Relay #2

Normally-open and normally-closed relay contacts to control external devices,

Function of relay contact activation determined by AUX Relay #2 option switch settings. (For connection of Class

2, low voltage (<32 V), DC or AC, max 5 Amps, power sources only)

ALARM

RESET

1

SHADOW INTERRUPT

EXIT

Aux Relay

N.C.
COM
N.O.

Class 2 Power Source

(32 V max, 5 A max)

+

Warning Light

AUX RELAY WIRING EXAMPLE

Access Device

Exit Input

Shadow Input

AUX Relay 1

C

NO

Auxiliary

Command

SAMS WIRING WITH RELAYS NOT ENERGIZED

Dipswitch settings for AUX Relay 1:

1-OFF, 2-OFF, 3-ON

Main Board

Expansion Board

Barrier Arm Operator