Troubleshooting – Controlled Products Systems Group CSW24V User Manual

Page 43

Advertising
background image

41

TROUBLESHOOTING CHART

TROUBLESHOOTING

FAULT

POSSIBLE CAUSES

CORRECTIONS

Accessories

connected to

Accessory power

not working

correctly, turning

off, or resetting.

a) Accessory power protector active
b) Defective control board

a)

Disconnect all accessory powered devices and measure accessory power voltage (should

be 23 – 30 Vdc). If voltage is correct, connect accessories one at a time, measuring

accessory voltage after every new connection.

b) Replace defective control board

Quick Close not

working correctly.

a) Quick Close setting incorrect
b)

CLOSE EYES/Interrupt loop detector or loop

wire defective

c) Defective Expansion board

a) Check that Quick Close setting is ON
b) Check operation of CLOSE EYES/Interrupt Loop detector
c) Replace defective Expansion board

Anti-Tailgating not

working correctly.

a) Anti-Tail setting incorrect
b)

CLOSE EYES/Interrupt loop detector or loop

wire defective

c) Defective Expansion board

a) Check that Anti-Tail setting is ON
b) Check operation of CLOSE EYES/Interrupt Loop detector
c) Replace defective Expansion board

AUX Relay not

working correctly.

a) AUX Relay setting incorrect
b) AUX Relay wiring incorrect
c) Defective Expansion board

a) Check AUX Relay switches settings
b) Check that wiring is connected to either N.O. and COM or to N.C. and COM.
c) Set AUX Relay to another setting and test. Replace defective expansion board.

Advertising