Adjustment, Learn limits – Controlled Products Systems Group RSW12V User Manual

Page 20

Advertising
background image

19

ADJUSTMENT

» LEARN LIMITS

SINGLE GATE LEFT-HAND SIDE

Close the gate. Make sure the operator arm is properly seated on the output
shaft (the pin must fit into the slot). Make sure the handle is released on the
operator arm and the learn limit cam is touching the learn limit switch.

PROGRAM OPEN

Manually open the gate to the desired open position.

Tighten the handle on the operator arm.

Press and release the LEARN LIMITS BUTTON. The SET OPEN LIMIT LED will
blink.
Press and release the LEARN LIMITS button again. The control board will beep
and the SET CLOSE LIMITS LED will blink.

PROGRAM CLOSE

Press and hold the GATE 1 left button to move the gate to the desired CLOSED
position. When the gate is in the desired position, release the button.
NOTE: The GATE 1 right and left buttons can be used to jog the gate back and
forth as needed.
When gate is in the desired CLOSED position, press and release the
LEARN LIMITS button. The control board will beep and the SET CLOSE LIMITS
LED will stop blinking.

Programming is now complete. If the SET OPEN LIMIT LED continues to blink, repeat
programming. If the problem continues, see below.
Test the limits by pressing the SINGLE BUTTON to open and close the gate.

1

3
4
5

Inside

Pr

oper

ty

Inside

Pr

oper

ty

GATE 2

SET

CLOSE

LIMIT

GATE 1

SET

CLOSE

LIMIT

GAT

A

SET

OPEN

LIMIT

N

N

LEARN
LIMITS

GATE 2

SET

CLOSE

LIMIT

LEARN
LIMITS

GATE 1

SET

CLOSE

LIMIT

LEARN
LIMITS

GAT

A

SET

OPEN

LIMIT

Inside

Pr

oper

ty

SET

CLOS

DIAGNOSTIC

GATE 1

GATE 2

SET

CLOSE

LIMIT

LEARN
LIMITS

GATE 1

G

SET

CLOSE

LIMIT

LEARN
LIMITS

GATE

A

SET

OPEN

LIMIT

LEARN LIMITS Button

1

GATE 1 Left Button

4

"BEEP"

6

"BEEP"

5

LEARN LIMITS Button

LEARN LIMITS Button

3

2

IF THE LIMITS WILL NOT PROGRAM

Disconnect the operator by releasing the handle on the operator arm.

Manually close the gate.

Loosen the screw on the learn limit cam and rotate the learn limit cam so it is
touching the learn limit switch. Tighten the screw.

Tighten the handle on the operator arm.

Program the limits again.