S.E. Termination:

OFF = 4-wire,

ON = 2-wire with 10K

The Communicator

II

Wireless Transmitter Wiring Diagram

Wireless Receiver Wiring Diagram

MILLER EDGE, INC. • P.O. Box 159 • West Grove, PA 19390 • 610-869-4422 • Fax: 610-869-4423 • 1-800-220-3343 • www.milleredge.com

MILLER EDGE, INC. • 6809 South Harl Avenue • Suite A • Tempe, AZ 85283 • 480-755-3565 • Fax: 480-755-3558 • 1-800-887-3343

SAFETY EDGE (1 Relay)

(YELLOW LED)

(OFF = FAULT)

POWER

(GREEN LED)

(Normal = ON)

RELAY OUTPUT

JUMPER/SHUNT

LEFT PAIR=N/C

RIGHT PAIR=N/O

SIGNAL ACQUIRED

(GREEN LED)

ON when receiving signal

from transmitter with

correct address

POWER INPUT
(Red & Black Wires)
24V AC/DC
(100mA min.)

SAFETY EDGE (Relay1)
(White Wires)

SENSING EDGE INPUT

4-wire

(White, White, Black, Black)

2-wire

(none, White, Black, none)

8 POS. DIP

SWITCH SETTINGS

SAFETY EDGE

ACTIVE

(Yellow LED)

MAINTENANCE

REQUIRED

(Red LED)

FUTURE USE

(Green LED)

ON

5

4

3

2

1

OFF(0)

RECEIVER SWITCH SETTING

1 RECEIVER W/ 1 TRANSMITTER

1st 4 Address Switches

shown in the OFF position

ON

5

6

7

8

4

3

2

1

OFF(0)

TRANSMITTER SWITCH SETTING

1 RECEIVER W/ 1 TRANSMITTER

1st 4 Address Switches

shown in the OFF position

OFF

Safety Edge:

OFF = N/C

ON = N/O

Test Mode:

OFF = Normal Operation

B

A

T

T

E

R

Y

POWER

24V

NO

NC

NO

NC

CH1

CH2

GRN YEL GRN RED

1

2

3

4

5

ANT

Always OFF

Model # MWCR-04 Receiver is designed to work only

with the Model # MWCT-04 Transmitter

RED: 24V AC/ + 24V DC
BLACK: POWER GND.
WHITE: RELAY OUTPUTS

POWER ON

(GRN.)

RELAY

OUTPUT

(YEL.)

FUTURE

USE

(YEL.)

The Communicator

II

FUTURE

USED

(GRN.)

SENSING

EDGE

ACTIVE

(YEL.)

SIGNAL

AQUIRED

(GRN.)

MAINT.

REQUIRED

(RED)

Model # MWCR-04

228-26

1-800-220-3343

M

Miller Edge

Part # 400-MW-002
Rev. 002 / 8-18-10

U.S. Patent # 7,123,144

Advertising