DESCRIPTION OF SURGE SUPPRESSION TERMINAL BOARD

12

LC/VF Page

(+)

(-)

GND

(+)

(-)

GND

(+)

(-)

GND

(+)

(-)

GND

DOOR-NO

DOOR-NC

DOOR-C

GATE-NO

GATE-NC

GATE-C

12V

AC/DC

GATE
RELAY

DOOR
RELAY

POWER

POWER

INPUT

GND

INPUT

VCR-NO

VCR-C

TEL

LINE

TIP

RING

RS485 (1)

RS485 (2)

RS485 (3)

RS485 (4)

GATE

RELAY

DOOR

RELAY

CHASSIS
GROUND

POSTAL/EXIT

SW INPUT

VCR

RELAY

TELEPHONE LINE: Tip and Ring Connection.

POWER IN: 12 Vac transformer input.

RS485: Connect to corresponding RS485 terminals (-, +,
GND) of remote security devices.

DOOR RELAY: For allowing access through pedestrian gate or
door.

GATE RELAY: For use with gate operator to control access
through main vehicular gate.

VCR RELAY: For use with Time Lapse VCR. Each time access
is granted, the VCR Relay is activated for 5 seconds, allowing
recording of all access to facility.

POSTAL/EXIT SW INPUT: For allowing postal lock access to
pedestrian gate or door. Activates gate relay using gate strike
time.

CHASSIS GROUND: Entry Phone MUST be properly
grounded. Refer to “Grounding the Unit” and “ Earth Ground
Rod Installation”
sections.

POWER LED: Indicates Phone system has 12 Vac power.

GATE RELAY LED: Indicates gate relay is activated.

DOOR RELAY LED: Indicates door relay is activated.

2

4

5

6

7

8

1

1

2

3

4

5

6

7

8

9

10

11

3

3

3

3

9

10

11

It is MANDATORY that this unit is properly
grounded. The provided "chassis ground" wire
must be connected to the ground rod. If unit is
not grounded, lightning damage will occur.
Please refer to the owners manual for proper
grounding instructions.

MADE IN USA

eliteentryphone.com

Knockouts for

Incoming Wires

Removable Screw Terminal Connectors for Easy Wiring.

POWER IN

12V

AC/DC

NOTE: Telephone line used for Telephone Entry System must be a dedicated line.