Controlled Products Systems Group 23-213I User Manual

Page 11

Advertising
background image

Page 11 American Access Systems / Security Brands, Inc.

“102”

SUBMODE 102 (PROGRAM SLEEP CARD(S)) (BLOCK FORMAT)
DESCRIPTION: The SLEEP MODE is the mode of operation in which the unit shuts down and goes to sleep. Only
MANAGERS CARDS are accepted into the system in this mode. The SLEEP CARD is accepted into the system from
either of the 2 slaves. Each time the SLEEP CARD is entered, the sleep card #, date, and time are logged into the
history buffer and the unit toggles in and out of the SLEEP MODE.

To program in a new sleep card enter the 4 digit “MASTER CODE” on the master unit, followed by submode “102” then

enter the “STARTING CARD NUMBER” and then the “ENDING CARD NUMBER” you wish to program into the unit.

NOTE: EXAMPLES ARE USING FACTORY DEFAULT MASTER CODE OF 1251

(MASTER CODE) + 102 + (STARTING CARD NUMBER) + (ENDING CARD NUMBER)

EXAMPLE: TO VALIDATE A SINGLE CARD, CARD NUMBER 14.

1251 + 101 + 0027 +0027

EXAMPLE: TO VALIDATE CARDS 28 THRU 30

1251 + 102 + 0028 +0030

“103”

SUBMODE 103 (PROGRAM LATCH A CARD(S)) (BLOCK FORMAT)
DESCRIPTION: The LATCH A CARD(S) is used to toggle the output state of relay A. In most cases this card will be used
to hold a gate or door open. This card is accepted into the system from either of the slaves. Each time the LATCH A
CARD is entered, the latch A card number, date, and time are logged into the history buffer and the unit toggles the
output state of relay A. This code is not accessible while the unit is in the SLEEP MODE (see submode 102).

NOTE: IN ORDER TO UTILIZE THIS FUNCTION IN A GATE OPERATOR, THE OPERATOR MUST INCORPORATE AN “OPEN OVER-

RIDE CIRCUIT”.

To program in a new latch A card(s) enter the 4 digit “MASTER CODE” followed by submode “103” then enter the

“STARTING CARD NUMBER” and then the “ENDING CARD NUMBER” you wish to program into the unit.

(MASTER CODE) + 103 + (STARTING CARD NUMBER) + (ENDING CARD NUMBER)

EXAMPLE: TO VALIDATE A SINGLE CARD, CARD NUMBER 14.

1251 + 103 + 0014 + 0014

“104”

SUBMODE 104 (PROGRAM LATCH B CARD(S)) (BLOCK FORMAT)
DESCRIPTION: The LATCH B CARD is used to toggle the output state of relay B. In most cases this card will be used to
hold a gate or door open. This card is accepted into the system from either of the 2 slaves. Each time the LATCH
B card is entered the latch B card, date, and time are logged into the history buffer and the unit toggles the output
state of relay B. This card is not accessible while the unit is in the SLEEP MODE (see submode 102).

NOTE: IN ORDER TO UTILIZE THIS FUNCTION IN A GATE OPERATOR, THE OPERATOR MUST INCORPORATE AN “OPEN OVER-

RIDE CIRCUIT”.

To program in a new latch B card(S) enter the 4 digit “MASTER CODE” followed by submode “104” then enter the

“STARTING CARD NUMBER” and then the “ENDING CARD NUMBER” you wish to program into the unit.

(MASTER CODE) + 104 + (STARTING CARD NUMBER) + (ENDING CARD NUMBER)

EXAMPLE: TO VALIDATE A SINGLE CARD, CARD NUMBER 14.

1251 + 104 + 0014 + 0014

“105”

SUBMODE 105 (PROGRAM RELAY B CARD(S)) (BLOCK FORMAT)
DESCRIPTION: Relay B cards are used to activate relay B. Each time a relay B card is entered into the system, the
relay B card number, date, and time are logged into the history buffer. These cards are not accessible if the unit is in
the SLEEP MODE (see submode 102).

To program in relay B cards enter the 4 digit “MASTER CODE” followed by submode “105” followed by the “STARTING

CARD NUMBER” and then the “ENDING CARD NUMBER” you wish to program into the unit.

(MASTER CODE) + 105 + (STARTING CARD NUMBER) + (ENDING CARD NUMBER)

EXAMPLE: TO VALIDATE CARD NUMBERS 1157 THRU 1170 PRESS:

1251 + 105 + 1157 + 1170

.

Advertising