Group 200 (deleting cards), Group 300 (miscellaneous), Quick delete mode – Controlled Products Systems Group 23-213I User Manual

Page 13

Advertising
background image

Page 13 American Access Systems / Security Brands, Inc.

GROUP 200 (DELETING CARDS)

“200”

SubMode 200 (DELETE CARDS) (BLOCK FORMAT)

To delete a card(s) from memory, enter the 4 digit “MASTER CODE” followed by submode “200” followed by the “BE-

GINNING CARD NUMBER” and the “ENDING CARD NUMBER” to be deleted.

(MASTER CODE) + 200 + (BEGINNING CARD NUMBER) + (ENDING CARD NUMBER )

EXAMPLE: TO DELETE CARDS 120 THRU 155

1251 + 200 + 0120 +0155

EXAMPLE: TO DELETE A SINGLE CARD, SAY CARD NUMBER 38.

1251 + 200 + 0038 +0038

“QUICK DELETE MODE”

DESCRIPTION: Quick delete mode is another way to delete individual access cards from the system. The factory
default QUICK DELETE MASTER CODE is 1 2 5 3. (To change the quick delete master code see sub-mode 110.

To delete access cards enter the 4 digit “ QUICK DELETE MASTER CODE” followed by the “CARD NUMBER” you wish to

delete followed by the next “CARD NUMBER” and so on until you are finished and then press the # key to exit.

(QUICK DELETE MASTER CODE) + (CARD NUMBER) + (CARD NUMBER)... # TO EXIT

EXAMPLE: DELETE ACCESS CARD NUMBER 95

1253 + 0095 + #

“299”

SubMode 299 (CLEAR APB STATUS)
DESCRIPTION: This sub-mode is useful if a mistake is made and the Anti-PassBack status of all cards needs to be reset.

To erase the APB status of all cards in memory, enter the 4 digit “MASTER CODE” followed by submode “299” and then

reenter the 4 digit “MASTER CODE”. (MASTER CODE) + 299 + (MASTER CODE)
The LED’s will flash on and off while the memory is being cleared and the unit will respond with a GOODBEEP when
finished. An ERROR will occur and the unit will exit the program mode if the second master code is incorrect.

GROUP 300 (MISCELLANEOUS)

“300”

SubMode 300 (SET RELAY A OUTPUT TIME)
DESCRIPTION: The output time of relay A can be set anywhere from 1/2 to 99 seconds. The factory default is 1/2
second. In most cases this is adequate for gate operators. However, with door strikes and maglocks a longer output
time may be desired.

To set the output time of relay A in seconds enter the 4 digit “MASTER CODE” followed by submode “300” and then a 2

digit number corresponding to the number of seconds.

(MASTER CODE) + 300 + (SECONDS)
The unit will respond with a GOODBEEP and exit from the program mode once the seconds for relay B has been
accepted. If you enter 00 for seconds the output time is set to 1/2 second. Should you make an entry error, simply
press the * key and reenter the correct data.

“301”

SubMode 301 (SET RELAY B OUTPUT TIME)
DESCRIPTION: The output time of relay B can be set anywhere from 1/2 to 99 seconds. The factory default is 1/2
second. In most cases this is adequate for gate operators. However, with door strikes and maglocks a longer output
time may be desired.

To set the output time of relay B in seconds enter the 4 digit “MASTER CODE” followed by submode “301” and then a 2

digit number corresponding to the number of seconds.

(MASTER CODE) + 301 + (SECONDS)

The unit will respond with a GOODBEEP and exit from the program mode once the seconds for relay B has been

accepted. If you enter 00 for seconds the output time is set 1/2 second. Should you make an entry error, simply press

the * key and reenter the correct data.

Advertising