HOOKUP STEPS

(A). Your DKLP control unit operates on 12 to 24 volts AC or DC. Measure the voltage from the power source to
make sure it falls within these tolerances. Locate the two white wires on the circuit board and with the power off
connect them to a constant power supply.
(B). Connect the device to be controlled to the appropriate control leads of the 26-100 (See above diagram).
(C). Double Check your connections. When you are sure that everything is hooked up correctly, apply power to the
unit. A BEEP should be heard when you press a key on the keypad.

THE MASTER CODE AND ACCESS CODES
Your unit may be programmed with 100 multiple (4 digit) ACCESS CODES . The MASTER CODE is a 4 digit
programmable code used for accessing the program mode. Note: The model number of the unit is located on the
inside face of the unit. Note: The Master Code will not activate the relay!

SETTING OR RESETTING THE MASTER CODE
To set or reset the master code back to the factory default of 1 2 5 1 should you ever loose or forget you master code.
To do this follow these steps: (SEE PAGE 8 FOR LOCATION DIAGRAM)

(1). Disconnect power from the unit by disconnecting power from circuit board.

(2). Reconnect power while holding down the PROGRAM/RESET button.

(3). A single keybeep will be heard from the unit indicating that the master has been reset

This procedure can also be used to release a Latch Open if you forget your 4 digit Latch Code.

GOODBEEPS AND ERRORBEEPS
A standard beep will be heard each time a key is pressed. A “GOODBEEP” is represented by a series of quick beeps
in succession. An “ERRORBEEP” is represented by a single long beep.

THE IDLE MODE
The idle mode is the normal mode of operation. When in this mode the unit sits and waits for data from the keypad.
If a key is pressed from the keypad, you will have approximately 3 seconds between each keypress before the unit
resets.

THE PROGRAM MODE
The program mode is the mode of operation in which you will enter/change your access code. Upon entry, a
GOODBEEP will heard. A GOODBEEP will also be heard when you exit the program mode unless a keypress timeout
occurs in which case you will receive an ERRORBEEP. The program mode is accessed by entering the “MASTER CODE”
from the keypad. If the master code is valid, you will receive a GOODBEEP from the unit. In this mode you will have
approximately 15 seconds between keypresses. If this time is exceeded, you will receive an ERRORBEEP and the unit
will exit the program mode and return to the idle mode. To exit the program mode at any time, press #.

OPE R ATOR

White/White connect to

operator secondary power.

(12 to 24 volt)

Orange/Brown

connect to operator

open/close circuit.

(Blue not used)

OPE R ATOR WIR ING DIAGR AM