Installation and Wiring

5

AXB-232++ RS-232/422/485 Interface

Setting the RS-232/422 DIP switch

Set the stop bits, data bits, parity, and baud rate on the RS-232/422 DIP switch, located on the front

panel (see FIG. 1 on page 1). The AXB-232++ supports the following asynchronous data

standards:

Stop bits 1 and 2

Data bits 7, 8, and 9

Parity None, Odd, Even, Mark, and Space

Baud rates 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200 and 38,400.

57,600 is achieved by setting the DIP switch to 300 baud, and using the

BAUDMED

’ Send_Command (see the Send_Commands section on page 9 for

details).

115,200 is achieved by setting the DIP switch to 300 baud, and using the

BAUDHIGH

’ Send_Command (see the Send_Commands section on page 9 for

details).

The table below shows the RS-232/422 DIP switch numbers, functions, and their corresponding

values.

RS-232/422 DIP Switch Settings

Switch

1

2

3

4

5

6

7

8

Function Stop Bits Data Bits

Parity

Baud Rates

Setting

Off

Off

Off

Off

Off

Off

Off

Off

Value

2 bits

7 bits

Unused

300

On

On

On

Off

Off

On

Off

Off

1 bit

8 bits

Unused

600

Off

On

Off

Off

On

Off

Unused

1,200

On

On

Off

On

On

Off

Unused

2,400

Off

Off

On

Off

Off

On

Mark

4,800

On

Off

On

On

Off

On

Even

9,600

Off

On

On

Off

On

On

Odd

19,200

On

On

On

On

On

On

None

38,400

RS232/422

1

2

3

4

5

6

7

8

ON