9.

SETTING MENU LOCKOUTS

For security and ease of operation, any or all program menu items may be disabled. Each
function to be disabled is set to "1" in the menu items, " Loc 1"," Loc 2" or "Loc 3". These lockout
menu items may in turn be "locked-out" by installing an internal hardware shorting jumper. With
the jumper installed, the operator has access only to enabled menu items.

9.1

SETTING HARDWARE LOCKOUT JUMPER

Lockout Jumper

To access the jumper, remove the rear panel per Section 5.1.
Remove jumper "a" located on the lower portion of the power
supply board next to the input connectors (see figure at left) to
enable the software lockouts. Replace the jumper to disable
software lockouts.
Jumper Removed - Loc 1,2 and 3 are displayed as menu items
and allow other menu items to be locked out or enabled.
Jumper Installed - Loc1, 2 and 3 are not displayed on program
menu

Power Supply Board

Figure 9.1

a

9.2

SETTING SOFTWARE LOCKOUTS

When setting up the meter, it may be necessary to enable some of the menu items. Any digit
set to "1" in Loc 1, Loc 2 or Loc 3 indicates that item is locked out. By setting the digit to "0",
the item will appear in the menu. Be sure to reset the lockout bit to "1" after selection if you do
not want the value changed by the operator.
Note: The hardware lockout jumper must be removed to access Loc 1, 2 and 3 (see section
9.1)

1 2 3 4 5

Press the

key until Loc

1 is displayed.

Press

to display status

and select left digit. Press

again to select another

digit. Selected digit will flash.
"1" indicates the menu item
is disabled. "0" indicates the
item is enabled.

DIGIT SELECT KEY

VALUE SELECT KEY

Press to select "0" or "1"
for flashing digit
1 - Input type selection
2 - Meter setup, configura-
tion & decimal pt.
3 - Filter selection
4 -Scale or Lo, Hi Input
5 - Offset or Lo, Hi Reading

MENU KEY