OADING
The shelves can be easily and quickly reset into the vend
position (horizontal) by running the index finger of your
right hand up the side of the shelves. This “fanning” will
take only seconds to reset all 24 shelves.
The top shelf has an automatic empty device, the Empty
Rod, which can be seen to the left of the Shelf Assembly,
above the Coin Mechanism. When the last product is
sold and this top shelf drops, the bottom of the Empty
Rod trips the Empty Switch causing the Electronic
Acceptor to reject all coins. The display will continually
flash
&
also. Therefore, it is extremely
important to load product from the top down if the
vender will not be fully loaded during restocking. Coins
will be returned if the vender is sold out or if there is a
power outage.
Empty Rod
399-41
Magazine
Assembly
399-D1
Circuit Board
399-19
Coin Mechanism
Slugbuster 399-C103
MA-800 399-C65
Microcoin 399-C102
Coin Box
300-A69
Side Bar
2100-64
Door
399-B70
Security Frame
2100-63
LED Window
399-62
C
OIN
M
ECHANISM
R
EMOVAL
To remove the Coin Mechanism, first remove the
Empty Rod by dropping the top 2 shelves and disen-
gaging the Rod from the slot at the side and top of the
Magazine Assembly. To drop a shelf, use your finger
under the shelf to push the Shelf Wire back out of the
slot. Removing the Rod prevents the lever on the
Empty Switch from getting bent when the Coin
Mechanism is lifted upward upon removal.
Loosen, but do not remove, the 3 mounting screws
and simply lift the Coin Mechanism up far enough for
the Drive Cam to clear the Shelf Actuator.
When reinstalling the Coin Mechanism make sure that
the Drive Cam is positioned back into the Shelf
Actuator. If the Drive Cam is not inside of the Shelf
Actuator the coin mechanism frame will not fit flush
against the Shelf Assembly.
T
ROUBLE
S
HOOTING
6
3
SYMPTOMS
LED display out
‘E__1’
displayed
Product vended at
less than vend price
Motor runs, no shelf
drop
Inserted coin rejected
LOOK FOR
Power loss
Check for 24 volts
(+/- 15%) power
at the circuit
board where
power comes in
Shelf stuck, jammed
Motor burned out
‘A’
value changed
from
‘.25’
MA800 coin acceptor
not programmed cor-
rectly
Shelf wire damaged,
stuck
Power loss
Coin acceptor
malfunction
Top shelf down
NOTES
Check transformer.
See page 1 for power
requirements.
Check shelf that is
next to drop.
Not very likely.
See page 5 for
‘A’
value setting info.
See page 5 or MA800
manual.
Wire tension may be
too great, bend wire
back slightly to lessen
initial wire tension.
Check transformer.
Slugbuster – change
sample Quarter.
MA800 – see
manual, LED should
be green on MA800.
Display will read
‘SOLD OUT’
.
Power down machine for 5-10 seconds and power back up
Power down machine for 5-10 seconds and power back up