maInTenanCe

disassembling a strainer

To disassemble a strainer

1. Carefully clean strainer basket cover

plate to remove all foreign matter, and

remove the four bolts and washers from

the end cover plate.

2. Remove the end cover plate (cover plate

is on the top of FS/FSAA/FSA strainers)

and o-ring from the strainer housing.

3. Remove the strainer basket. This

may dislodge dirt and particles into

the strainer housing. Check inside the

strainer housing for any foreign material.

Be sure to wipe the housing clean, using

a soft cloth.

4. Clean the strainer basket by flushing

the basket with a liquid cleaning agent suited for your

application. A soft brush may be used to dislodge imbedded

particles. If the imbedded particles cannot be removed,

replace the basket.

5. Clean the inner face of cover plate, mating face of the

strainer body, and seal ring with a clean, soft, cloth.

6. Make sure the o-rings are cleaned of all dirt and grime.

Check the o-rings for damage. If the o-rings cannot be

cleaned or are damaged or frayed, replace them.

maintenance

It is very important to follow the strainer preventive

maintenance procedures to protect the strainer as well as

the metering system. Foreign matter that builds up inside

the strainer, including ice, can cause damage to the strainer

and the metering system. When foreign matter builds up

inside the strainer, it can cause pressure to build up inside

the strainer. This pressure can cause the strainer screen

to rupture. Foreign matter can then enter the metering

chamber. This can cause serious damage to the meter

resulting in failure of the meter.
The following strainer preventive maintenance precedures

will keep your strainer functioning properly, keep strainer

repair costs to a minimum, and insure the protection of

your metering system.

neWly InsTalled oR RePaIRed sysTems

• Check the strainer daily during the first 100 hours of

operation or until no more debris is found in the strainer.

• New or repaired piping can be the source of welding slag or

other foreign particles that can block or rupture the strainer

screen.

• Once a system is cleaned out, the strainer should be

checked several times every season. The frequency

depends on the specific service conditions, through put and

product cleanliness.

When an air eliminator is used with the strainer, it

must be installed vertically on the strainer.

Air Eliminators & Strainers

Never reuse PTFE O-rings. Always replace them even if

they appear to be in good condition.

Replace PTFE O-rings

Never tap the basket ends on a hard surface to dislodge

particles. This may dent the basket and make reassembly

difficult or cause improper sealing.

Installation and operation

1. flush all new systems

Flushing the system before the meter has been installed is the preferred first step. Thoroughly flush the lines until the system is

purged of all foreign materials. See Strainer Maintenance for disassembly and reassembly instructions.

2. Plan a location for the strainer in the system providing for the following requirements:

Make sure there is no pipe strain imposed upon the strainer or any other component part of the meter assembly. This means that

the meter and its accessories must not support the weight of the piping. Plan for enough space to allow clearance so that the

strainer basket cover and strainer basket can be easily removed.

3. Install the strainer

(1) Install the strainer

on the inlet side of the meter

(2) Bolt the strainer outlet to the inlet flanged connection of the meter.

(3) Then bolt the inlet piping to the inlet flanged connection of the strainer.

4. Check the strainer daily during the first 100 hours of operation

New or repaired piping can be the source of welding slag or other foreign material that will

block or rupture the strainer screen. or until no more debris is found in the strainer.

5. Inspect and clean the strainer basket regularly

To ensure proper operation.

6. follow strainer maintenance

Follow the steps

outlined in the Strainer Maintenance section of this manual.

Meter

Inlet Side

Advertising